2012
DOI: 10.1016/j.apradiso.2011.11.051
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of a CT ionization chamber for radiation field mapping

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0
2

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 7 publications
0
4
0
2
Order By: Relevance
“…In the work of Maia and Caldas (2005), a parallel-plate ionization chamber was evaluated in diagnostic radiology radiation qualities and its energy dependence was 2.6%. In the work of Perini et al (2012a), a pencil ionization chamber was characterized in the diagnostic radiology qualities, and presented an energy dependence of 3.0%. The correction factors were obtained normalizing the calibration coefficient obtained in each quality to the calibration coefficient of the RQR5 radiation quality.…”
Section: Calibration and Energy Dependencementioning
confidence: 99%
See 1 more Smart Citation
“…In the work of Maia and Caldas (2005), a parallel-plate ionization chamber was evaluated in diagnostic radiology radiation qualities and its energy dependence was 2.6%. In the work of Perini et al (2012a), a pencil ionization chamber was characterized in the diagnostic radiology qualities, and presented an energy dependence of 3.0%. The correction factors were obtained normalizing the calibration coefficient obtained in each quality to the calibration coefficient of the RQR5 radiation quality.…”
Section: Calibration and Energy Dependencementioning
confidence: 99%
“…At the Calibration Laboratory of the IPEN (LCI) some ionization chambers were designed and developed for diagnostic radiology (Perini et al, 2012a) and radiotherapy (Neves et al, 2012). These ionization chambers presented satisfactory results to be applied in calibration laboratories and medical clinics.…”
Section: Introductionmentioning
confidence: 99%
“…Estas diferenças estão relacionadas ao material que ela foi constituída e à disposição geométrica de seus componentes. Esta câmara de ionização já foi avaliada para dosimetria de feixes padrões de TC, com resultados dentro das normas internacionais [3,4].…”
Section: Introductionunclassified
“…Figura 1: Câmara de ionização tipo lápis avaliada neste trabalho (a) e esquema do volume sensível, com os materiais constituintes (b). Figura modificada de[3].…”
unclassified
“…In order to construct an ionization chamber that attend the characteristics of an ideal dosimeter with requirements for a work standard, in this work the development and characterization of a new plane-parallel ionization chamber to be utilized in low-energy X-ray beam qualities for radiotherapy is presented. The main motivation for the development and characterization of this new ionization chamber was the possibility of its utilization at the Calibration Laboratory of IP-EN (LCI) as a work standard; and, besides that, the LCI group presents a previous knowledge in the development of ionization chambers for use in diagnostic radiology and radiotherapy energy ranges [11,12]. Furthermore, the ionization chamber designed and developed in this work was planned to be a radiation detector of low cost, easy to assemble, robust, and utilizing only easily commercially available Brazilian materials.…”
Section: Introductionmentioning
confidence: 99%