2017
DOI: 10.1109/tpwrd.2016.2606431
|View full text |Cite
|
Sign up to set email alerts
|

Characteristics of Harmonic Distortions in Residential Distribution Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 84 publications
(28 citation statements)
references
References 14 publications
0
27
0
1
Order By: Relevance
“…This was illustrated by several studies on the impact of compact fluorescent lamps and LED lamps on the waveform distortion. Simulation studies concluded that the voltage and current distortion would increase [71,72]; measurements showed however that this was not the case and that the distortion was simply not impacted [73][74][75][76]. Acceptable harmonic models exist for the components of the power system (cables, lines and transformers) but several barriers remain before a complete model is available for use in hosting-capacity studies:…”
Section: Calculation Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This was illustrated by several studies on the impact of compact fluorescent lamps and LED lamps on the waveform distortion. Simulation studies concluded that the voltage and current distortion would increase [71,72]; measurements showed however that this was not the case and that the distortion was simply not impacted [73][74][75][76]. Acceptable harmonic models exist for the components of the power system (cables, lines and transformers) but several barriers remain before a complete model is available for use in hosting-capacity studies:…”
Section: Calculation Methodsmentioning
confidence: 99%
“…This holds for the aggregation between different new devices (e.g., between different PV inverters) but also for the aggregation between the new devices and the background distortion. The aggregation between individual wind turbines has been studied by some authors [90][91][92] but it is not known if similar conclusions hold for PV inverters, EV chargers or other large low-voltage equipment like heat pumps [22,71,93].…”
Section: Calculation Methodsmentioning
confidence: 99%
“…Estimation errors occur due to the phase displacement of sin(ωt) and the fundamental in v P CC , which are caused by the relative phase and magnitude of the voltage harmonics in v P CC . Replacing the ZCD by a PLL avoids such effects, however, it must be considered that the T HD V in residential feeders is usually in the range (1%,3%) [58], which limits the potential phase errors to less than a maximum 3.3 degrees. The effects of the voltage harmonic distortion on the estimation of V P CC,peak are mitigated by the outer voltage control loop of the PQE, which adjusts the amplitude of i P QE .…”
Section: Implementation Of the Pqe Controllermentioning
confidence: 99%
“…On the other hand, power electronic devices, as in the case of voltage source converters, switch-mode power supplies, power electronic converters and fluorescent lights (with electronic ballasts), which are some kind of power electronic devices [18][19][20]. The distortions in the power network can influence negatively the functions of some equipment, making them respond in an unpredicted manner when subjected to multiple frequencies [21][22][23][24]. Due to this fact methods to monitoring the sources of harmonics system have been developed to quantify/qualify the effects of the distortion in the system [25][26][27][28][29].…”
Section: Introductionmentioning
confidence: 99%