Characterisation of neutron field in the polyethylene neutron irradiator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…Of all irradiation chambers, fast neutrons comprise no more than 20% of all neutrons travelling through the chambers. This indicates the efficiency of high-density polyethylene in moderating fast neutrons [16][17]. Figure 8 illustrate the spatial distribution of neutrons in the room with radial beam tube while Figure 9 displays the energy distribution at the end of the radial beam tube.…”
Section: Resultsmentioning
confidence: 97%
“…Of all irradiation chambers, fast neutrons comprise no more than 20% of all neutrons travelling through the chambers. This indicates the efficiency of high-density polyethylene in moderating fast neutrons [16][17]. Figure 8 illustrate the spatial distribution of neutrons in the room with radial beam tube while Figure 9 displays the energy distribution at the end of the radial beam tube.…”
Section: Resultsmentioning
confidence: 97%
“…1 and 2. It is used for experiments with radionuclide neutron sources and electronic neutron generators [3]. The neutron generator was placed inside a central channel of the polyethylene box of 50 x 50 cm x 100 cm, the cadmium covered detector was placed in one of the dry experimental channels with diameter of 7 cm, the centre of the detectors was located 10.5 cm from the centre of the tube.…”
Section: Experimental Set-upmentioning
confidence: 99%
“…In case A (moderated geometry), the generator was placed inside PE block of 50 x 50 x 100 cm; the detectors were placed in dry channels with diameter of 7 cm. One detector was simulated as bare, another was covered by 1 mm thick cadmium sheet with density of 8.65 g/cm 3 .…”
Section: Fig 3 Geometry Used In Calculationsmentioning
confidence: 99%