Indirect Calorimetry 2015
DOI: 10.3920/978-90-8686-261-0_2
|View full text |Cite
|
Sign up to set email alerts
|

Chapter 2: Design of climate respiration chambers, adjustable to the metabolic mass of subjects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
22
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 26 publications
(22 citation statements)
references
References 18 publications
0
22
0
Order By: Relevance
“…Upon arrival, eggs were placed in one climate respiration chamber per treatment. In climate respiration chambers, climate conditions such as temperature, relative humidity, and CO 2 levels can be controlled strictly in an airtight situation [24]). Three regimes with 310 eggs each (to allow for an estimated hatchability of 80%) were used for incubation: 24L; an intermittent light-dark schedule (12L:12D) that started with the light period on embryonic day (E)0; or 24D.…”
Section: Methodsmentioning
confidence: 99%
“…Upon arrival, eggs were placed in one climate respiration chamber per treatment. In climate respiration chambers, climate conditions such as temperature, relative humidity, and CO 2 levels can be controlled strictly in an airtight situation [24]). Three regimes with 310 eggs each (to allow for an estimated hatchability of 80%) were used for incubation: 24L; an intermittent light-dark schedule (12L:12D) that started with the light period on embryonic day (E)0; or 24D.…”
Section: Methodsmentioning
confidence: 99%
“…The CRC was maintained at overpressure (50-100 Pa) to prevent unfiltered air influx, and to maintain hygiene. More information on CRC can be found in Heetkamp et al (2015). For experiment 1, 600 chickens in total (i.e.…”
Section: Study Populationmentioning
confidence: 99%
“…Consequently, the experimental period started 1 d later for DF-pigs than for NF-pigs. Each chamber (27) contained one pen of 1•75 × 2•85 m with 40 % slatted floor. Temperature was maintained at 20°C and relative humidity at 65 %.…”
Section: Experimental Designmentioning
confidence: 99%
“…The equipment that was used to perform the gas exchange measurements is in detail described by Heetkamp et al (27) . A CO 2 recovery test was performed as a full system check, prior to the start of the experiment (27) . In the four chambers, 100•3, 100•2, 100•3 and 99•9 % of CO 2 released were recovered.…”
Section: Measurementsmentioning
confidence: 99%