2008 Joint International Conference on Power System Technology and IEEE Power India Conference 2008
DOI: 10.1109/icpst.2008.4745171
|View full text |Cite
|
Sign up to set email alerts
|

Challenges with Multi-Terminal UHVDC Transmissions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
37
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 45 publications
(37 citation statements)
references
References 4 publications
0
37
0
Order By: Relevance
“…In case of a non-sustained fault, the stations and the line can be re-energized. This operation sequence takes at least a few 100ms [23], [31], [32] up to a few seconds [33], but is well suited for point-to-point connections. De-energizing the entire HVDC networks has also been suggested [24], [34], [35], but it is surely limited to small systems with only three or four terminals [36].…”
Section: Hvdc Networkmentioning
confidence: 99%
“…In case of a non-sustained fault, the stations and the line can be re-energized. This operation sequence takes at least a few 100ms [23], [31], [32] up to a few seconds [33], but is well suited for point-to-point connections. De-energizing the entire HVDC networks has also been suggested [24], [34], [35], but it is surely limited to small systems with only three or four terminals [36].…”
Section: Hvdc Networkmentioning
confidence: 99%
“…This may in turn lead to an effective variation of P dc i that is delayed with respect to the one predicted by (8).…”
Section: Effects Of Delaysmentioning
confidence: 99%
“…Conventionally, in an MT-HVDC system, only one of the converters (indexed by k) regulates the DC voltage, while all the others control the real power exchanged between the AC and the DC sides [8]- [10]. In fact, converter k plays the role of the slack bus that maintains the power balance within the DC grid, and the DC grid can be considered as a real power exchange center between different AC areas.…”
Section: Hvdc Convertermentioning
confidence: 99%
“…This is partially due to the fact that VSC-HVDC is a relatively new technology, the total installed capacity of VSC-HVDC is substantially lower than LCC-HVDC and there has not yet been any reported major VSC-HVDC disruption caused by GIC. In fact, VSC-HVDC is considered to be immune to GIC events in certain research [18], since the converters operate at much higher voltage levels than the induced potential. However, the effects of abnormal harmonics generated by saturated converter transformers were not discussed in [18].…”
Section: Introductionmentioning
confidence: 99%
“…In fact, VSC-HVDC is considered to be immune to GIC events in certain research [18], since the converters operate at much higher voltage levels than the induced potential. However, the effects of abnormal harmonics generated by saturated converter transformers were not discussed in [18]. This paper addresses this issue.…”
Section: Introductionmentioning
confidence: 99%