2011
DOI: 10.1016/j.chroma.2010.10.056
|View full text |Cite
|
Sign up to set email alerts
|

Challenge in the speciation of nitrogen-containing compounds in heavy petroleum fractions by high temperature comprehensive two-dimensional gas chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
41
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 69 publications
(42 citation statements)
references
References 40 publications
1
41
0
Order By: Relevance
“…the detection of nitrogen-containing compounds and the analysis on vacuum gas oil (VGO), high modulation period (20s -30s) is needed. In this case, wide bore first column with bigger diameter are used to make the first dimension peak wider (Dutriez et al, 2009(Dutriez et al, , 2010(Dutriez et al, , 2011.…”
Section: Factors Affecting 2d-gc Retention Time and Separationmentioning
confidence: 99%
See 2 more Smart Citations
“…the detection of nitrogen-containing compounds and the analysis on vacuum gas oil (VGO), high modulation period (20s -30s) is needed. In this case, wide bore first column with bigger diameter are used to make the first dimension peak wider (Dutriez et al, 2009(Dutriez et al, , 2010(Dutriez et al, , 2011.…”
Section: Factors Affecting 2d-gc Retention Time and Separationmentioning
confidence: 99%
“…Fast time-of-flight mass spectrometers (TOFMS) that operate with spectral acquisition rates of 100-200 Hz are well-suited for GC × GC and have been used for numerous studies. On the other hand, element-specific detectors such as sulphur, nitrogen chemiluminescence detections (SCD, NCD), have been used for nitrogen containing and sulphur containing compounds, respectively (Dutriez et al, 2011;Zrostlíková et al, 2003).…”
Section: Detectormentioning
confidence: 99%
See 1 more Smart Citation
“…Even if sulfur and nitrogen characterization is very difficult [11,12] for VGO fraction, the main mechanism for each reaction type can be defined [3] as described in following sections. Fig.…”
Section: Mechanism Descriptionmentioning
confidence: 99%
“…In addition, IL stationary phases allow for higher temperature limits (300 °C) in comparison to the 50% LC-DMPS phase (270 °C). IL stationary phases have been used for the separation of alkyl phosphates [36], fatty acids [3840], PASHs [19], flavors and fragrances [37], pesticides [38], and polycyclic aromatic nitrogen heterocycles [38]. …”
Section: Introductionmentioning
confidence: 99%