Retention indices (I) for 45 polycyclic aromatic hydrocarbons (PAHs) and 63 methyl-substituted PAHs were determined by gas chromatography - mass spectrometry (GC-MS) using two different stationary phases: a Rxi-PAH phase (a "higher phenyl-content stationary phase") and a 50% (mole fraction) liquid crystalline dimethylpolysiloxane phase. Retention data were obtained for parent PAHs from molecular mass (MM) 128 g/mol (naphthalene) to 328 g/mol (benzo[c]picene) and for 12 sets of methyl-PAHs (methylfluorenes, methylanthracenes, methylphenanthrenes, methylfluoranthenes, methylpyrenes, methylbenz[a]anthracenes, methylbenzo[c]phenanthrenes, methylchrysenes, methyltriphenylenes, methylbenzo[a]pyrenes, methylperylenes, and methylpicenes). Molecular shape descriptors such as length-to-breath ratio (L/B) and thickness (T) were determined for all the PAHs studied. Correlation between I and L/B ratio was evaluated for both stationary phases with a better correlation observed for the 50% liquid crystalline phase (correlation coefficients ranging from 0.22 to 1.00). Graphical Abstract GC separation of six methylchrysene isomers (m/z 242) on two different stationary phases: 50 % phenyl-like methylpolysiloxane phase and 50 % liquid crystalline phase. Retention indices (I) are plotted as a function of L/B for both phases. The data marker numbers identify each isomer based on methyl-substitution position.
A normal-phase liquid chromatography (NPLC) fractionation procedure was developed for the characterization of a complex mixture of polycyclic aromatic hydrocarbons (PAHs) from a coal tar sample (Standard Reference Material (SRM) 1597a). Using a semi-preparative aminopropyl (NH2) LC column, the coal tar sample was separated using NPLC based on the number of aromatic carbons; a total of 14 NPLC fractions were collected. SRM 1597a was analyzed before and after NPLC fractionation by using gas chromatography/mass spectrometry (GC/MS) with a 50% phenyl stationary phase. The NPLC-GC/MS method presented in this study allowed for the identification of 72 PAHs and 56 MePAHs. These identifications were based on the NPLC retention times for authentic reference standards, GC retention times for authentic reference standards, and the predominant molecular ion peak in the mass spectrum. Most noteworthy was the determination of dibenzo[a,l]pyrene, which could not be measured directly by GC/MS because of low concentration and co-elution with dibenzo[j,l]fluoranthene. The NPLC-GC/MS procedure also allowed for the tentative identification of 74 PAHs and 117 MePAHs based on the molecular ion peak only. This study represents the most comprehensive qualitative characterization of SRM 1597a to date.
This article presents the first application of gold nanoparticles deposited capillaries as pre-concentration devices for in-capillary microextraction CZE and their use for the analysis of monohydroxy-polycyclic aromatic hydrocarbons in synthetic urine samples. The successful separation of 1-hydroxypyrene, 9-hydroxyphenanthrene, 3-hydroxybenzo[a]pyrene (3-OHbap), 4-hydroxybenzo[a]pyrene and 5-hydroxybenzo[a]pyrene under a single set of electrophoretic conditions is demonstrated as well as the feasibility to obtain competitive ultraviolet absorption LOD with commercial instrumentation. Enrichment factors ranging from 87 (9-OHphe) to 100 (3-OHbap) made it possible to obtain LOD ranging from 9 ng/mL (9-OHphe and 3-OHbap) to 14 ng/mL (4-hydroxybenzo[a]pyrene).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.