2016
DOI: 10.1039/c6ay02142e
|View full text |Cite
|
Sign up to set email alerts
|

Centri-voltammetric detection of epinephrine

Abstract: In this study, centri-voltammetry was applied to epinephrine detection for the first time.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 27 publications
0
5
0
Order By: Relevance
“…As can be seen from the Figure, an increase in the peak currents were obtained up to 1500 rpm where a decrease in the current value was observed at centrifugation speeds higher than that. As explained before, this might be attributed to the disintegration of FA included 4NC−NO 2 layer onto the electrode surface .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…As can be seen from the Figure, an increase in the peak currents were obtained up to 1500 rpm where a decrease in the current value was observed at centrifugation speeds higher than that. As explained before, this might be attributed to the disintegration of FA included 4NC−NO 2 layer onto the electrode surface .…”
Section: Resultsmentioning
confidence: 99%
“…By applying centrifuga-tion, the analyte is deposited onto the electrode surface and without engaging any separation techniques, the analyte's redox behaviour is monitored voltammetrically [28]. Up to now, metallic substances [29,30] together with biologically important analytes [31,32,33,34,35] were detected by this method. Also, the electrode was modified with suitable enzymes [36,37] or cell lines [38] and various biocentri-voltammetric methods were developed.…”
Section: Introductionmentioning
confidence: 99%
“…The advantages of nanomaterials in the electrochemical systems have been obvious and demonstrated with different groups for some time [43][44][45][46]. It has been known that the addition of nanomaterials into these systems increases the conductivity hence fastens the electrochemical transfer that results with the increment in sensitivity [43].…”
Section: Electron Microscopic Characterization Of Mwcntà Ptà Au and I...mentioning
confidence: 99%
“…In order to obtain more efficient deposition of the analyte, sometimes a suitable carrier has also been used [48,49] . As a result more sensitive analysis has been done [50–53] . In the present work, centri‐voltammetry was again attained for GSH detection.…”
Section: Introductionmentioning
confidence: 99%
“…[48,49] As a result more sensitive analysis has been done. [50][51][52][53] In the present work, centri-voltammetry was again attained for GSH detection. In our previous centri-voltammetric GSH detection, silica gel was acted as a carrier precipitate in the presence of gold nanoparticles.…”
Section: Introductionmentioning
confidence: 99%