Cemented and cementless dual mobility cups show similar fixation, low polyethylene wear, and low serum cobalt-chromium in elderly patients: a randomized radiostereometry study with 6 years’ follow-up

Abstract: Background and purpose: Dual mobility (DM) articulation total hip arthroplasty (THA) is used increasingly to reduce dislocation risk. We investigated cup fixation, polyethylene (PE) wear, serum chromium and cobalt ions, and their correlation to physical activity in patients with DM cups at 6-year follow-up.Patients and methods: In a patient-blinded RCT, 60 patients with hip osteoarthritis at a median age of 74 years (70–82) were randomly allocated to cemented (n = 30) or cementless hydroxyapatite-coated (n = 3… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 33 publications
0
2
0
Order By: Relevance
“…Only a few studies in the literature performed a kinematic analysis using 3D videofluoroscopy [9,[25][26][27], but no purely kinematic-focused trial in vivo was performed using MB-RSA for an anterior approach, mobile bearing, flat tibia ankle arthroplasty, to the best of our current knowledge. RSA has instead been typically used, in the last two decades, for the demonstration of early migrations, for the prediction of possible mobilizations, and the analysis of micromovements at the bone-prosthesis interface of various joints but without focusing on the movement relationships between the prosthetic components [28][29][30][31][32][33][34]. Similar studies to perform an equal comparison of the data collected in this study are therefore not present in the literature.…”
Section: Discussionmentioning
confidence: 99%
“…Only a few studies in the literature performed a kinematic analysis using 3D videofluoroscopy [9,[25][26][27], but no purely kinematic-focused trial in vivo was performed using MB-RSA for an anterior approach, mobile bearing, flat tibia ankle arthroplasty, to the best of our current knowledge. RSA has instead been typically used, in the last two decades, for the demonstration of early migrations, for the prediction of possible mobilizations, and the analysis of micromovements at the bone-prosthesis interface of various joints but without focusing on the movement relationships between the prosthetic components [28][29][30][31][32][33][34]. Similar studies to perform an equal comparison of the data collected in this study are therefore not present in the literature.…”
Section: Discussionmentioning
confidence: 99%
“…Differences in wearing rate between cemented and cementless cups were taken into consideration, but the findings support that they have similar results with highly crosslinked vitamin-E-infused liners when used for primary THA surgery[ 22 ].…”
Section: Limitationsmentioning
confidence: 98%