2018
DOI: 10.1186/s12871-018-0651-0
|View full text |Cite
|
Sign up to set email alerts
|

Cell salvage using the continuous autotransfusion device CATSmart – an observational bicenter technical evaluation

Abstract: BackgroundThe use of cell salvage and autologous blood transfusion has become an important method of blood conservation. So far, there are no clinical data about the performance of the continuous autotransfusion device CATSmart.MethodsIn total, 74 patients undergoing either cardiac or orthopedic surgery were included in this prospective, bicenter and observational technical evaluation to validate red cell separation process and washout quality of CATSmart. The target of red cell separation process was defined … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
10
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 9 publications
1
10
0
1
Order By: Relevance
“…Mansour et al 15.2%; P < 0.001; fig. 4A) during the second cycle in the pretreated and posttreated blood, respectively.…”
Section: Perioperative Medicinementioning
confidence: 92%
See 1 more Smart Citation
“…Mansour et al 15.2%; P < 0.001; fig. 4A) during the second cycle in the pretreated and posttreated blood, respectively.…”
Section: Perioperative Medicinementioning
confidence: 92%
“…Blood units were diluted in normal saline (0.9% NaCl; Macopharma, France) up to 1,200 ml (including 200 ml of collection reservoir priming) to obtain clinically relevant hematocrits of 14.4% (13.1 to 15.3%), corresponding to initial hematocrits measured in blood collection reservoir during cardiac and orthopedic surgeries (ranging between 10 and 20%) while preserving between-subject heterogeneity. 7,[15][16][17] A high concentration of unfractionated heparin (Choay heparin; Sanofi-Aventis, France) was added to whole blood before dilution in saline (fig. 1); the final concentration of heparin in the collection reservoir was 12 IU/ml, to evaluate heparin washout in worst-case clinical conditions.…”
Section: Perioperative Medicinementioning
confidence: 99%
“… 18 Centrifugal technology has been shown to effectively reduce the non-cellular load by about 90%. 8 , 19 , 20 The centrifugal autoLog ® procedure resulted in a removal of 98% of the total protein level. The reduction of smaller solutes was less effective, with about 20% of the small-molecule glucose and ion potassium left in the concentrated red cell product.…”
Section: Discussionmentioning
confidence: 99%
“…Оправданно это или нет, будущее покажет. Во всяком случае, качество реинфузата существенно не ухудшилось [11,12].…”
Section: современные селл-сейверыunclassified