2010
DOI: 10.1016/j.jclinane.2009.08.003
|View full text |Cite
|
Sign up to set email alerts
|

Caudally threaded epidural catheter following a single-shot caudal block in a high-risk neonate: a combined caudal-epidural technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
2
0
1

Year Published

2011
2011
2014
2014

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 11 publications
(9 reference statements)
0
2
0
1
Order By: Relevance
“…9,[14][15][16][17][18][19][20][21][22][23][24][25] In contrast, only a few case series and reports describing catheter threading from a lumbar insertion point have been published. 11,25 There are multiple reasons for the popularity of the caudal approach among pediatric anesthesiologists.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…9,[14][15][16][17][18][19][20][21][22][23][24][25] In contrast, only a few case series and reports describing catheter threading from a lumbar insertion point have been published. 11,25 There are multiple reasons for the popularity of the caudal approach among pediatric anesthesiologists.…”
mentioning
confidence: 99%
“…Des décennies plus tard, De nombreux comptes rendus, particulièrement dans la littérature d'anesthésie pédiatrique, rapportent la réussite de techniques d'insertion péridurale caudales et l'insertion du cathéter jusqu'aux niveaux thoracique et lombaire. 9,[14][15][16][17][18][19][20][21][22][23][24][25] En revanche, seules quelques séries de cas décrivant l'insertion d'un cathéter depuis un point d'insertion lombaire ont été publiées. 11,25 Les raisons pour la popularité de l'approche caudale avec les anesthésiologistes pédiatriques sont multiples.…”
unclassified
“…On the other hand, we feel that the editorialists go too far in their criticism and appear to question the practicality of many regional anesthetic techniques in infants. We have published two case reports describing modifications of the caudally threaded epidural catheter technique in two syndromic infants who required palliative surgeries and in whom it was requested that general anesthesia with endotracheal intubation be avoided (3,4). We therefore believe that there is definitely a role for advanced regional anesthesia techniques in infants and neonates and that the contributions of investigators such as Willschke are extremely important.…”
mentioning
confidence: 99%