2021
DOI: 10.1016/j.cej.2021.129811
|View full text |Cite
|
Sign up to set email alerts
|

Cationic cellulose nanocrystals for fast, efficient and selective heparin recovery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 15 publications
(17 citation statements)
references
References 46 publications
0
17
0
Order By: Relevance
“…The stretching vibration peaks located at 3300 cm -1 and 2900 cm -1 in RC are corresponding to -OH and -C-H of polysaccharide molecular skeleton (Kamtsikakis et al 2021). MdC-Op shows a more obvious peak at 1060 cm -1 , which is recognized as C-O-C generated by the etherification between CHPTAC and RC (Liu et al 2021). And the peaks at 1290 cm -1 and 1477 cm -1 are corresponding to -CH 3 and N-CH 3 of CHPTAC (Fang et al 2021).…”
Section: Structural Characterization Of Mdc-opmentioning
confidence: 96%
“…The stretching vibration peaks located at 3300 cm -1 and 2900 cm -1 in RC are corresponding to -OH and -C-H of polysaccharide molecular skeleton (Kamtsikakis et al 2021). MdC-Op shows a more obvious peak at 1060 cm -1 , which is recognized as C-O-C generated by the etherification between CHPTAC and RC (Liu et al 2021). And the peaks at 1290 cm -1 and 1477 cm -1 are corresponding to -CH 3 and N-CH 3 of CHPTAC (Fang et al 2021).…”
Section: Structural Characterization Of Mdc-opmentioning
confidence: 96%
“…When the solution was switched to buffer again, a slight increase in frequencies was observed for all binders, implying that a small portion of the binders was washed away by the buffer. 41 A compromised binding between heparin and PCS0 was also observed, as evidenced by a less sharp frequency drop in PBS compared to that in PB (Figures 3a and S5a). No obvious change was observed with PCS4 and PCS10, demonstrating the excellent heparin-capture ability even under physiologically relevant conditions.…”
Section: ■ Results and Discussionmentioning
confidence: 88%
“…The downward trajectory was less steep after the initial drop, which indicated that the heparin on the sensor was gradually saturated by binders. When the solution was switched to buffer again, a slight increase in frequencies was observed for all binders, implying that a small portion of the binders was washed away by the buffer . A compromised binding between heparin and PCS0 was also observed, as evidenced by a less sharp frequency drop in PBS compared to that in PB (Figures a and S5a).…”
Section: Resultsmentioning
confidence: 93%
“…Graft polymerization is one of the widely used approaches for modification of chemical and physical properties of CNCs. For instance, Liu et al and Hemraz et al have extensively investigated surface-initiated grafting polymerization reactions onto the surface of CNCs. Their approaches involved several steps for grafting of cationic polymers.…”
Section: Introductionmentioning
confidence: 99%