2018
DOI: 10.1109/tia.2017.2768531
|View full text |Cite
|
Sign up to set email alerts
|

Cascaded Open-End Winding Transformer Based DVR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 32 publications
(11 citation statements)
references
References 35 publications
0
11
0
Order By: Relevance
“…The voltage applied to the primary of the DVR transformer is combination of voltages at different frequencies [24], [48]. The sum of the maximum flux densities (at the different frequency components) should be less than the permissible maximum value of the ac flux density Bac_max_eqa and is given by 𝐡 π‘Žπ‘_max _π‘’π‘žπ‘’ = 𝐡 1π‘šπ‘Žπ‘₯ cos(πœ”π‘‘ + 𝛿 1 ) + 𝐡 2π‘šπ‘Žπ‘₯ cos(2πœ”π‘‘ + 𝛿 2 ) … 𝐡 π‘›π‘šπ‘Žπ‘₯ cos(π‘›πœ”π‘‘ + 𝛿 𝑛 ) (8) where B1max, B2max … Bnmax are the maximum flux densities of voltages at multiple frequency components x=1,2…n respectively.…”
Section: Calculation Of Rated Ac Voltagementioning
confidence: 99%
“…The voltage applied to the primary of the DVR transformer is combination of voltages at different frequencies [24], [48]. The sum of the maximum flux densities (at the different frequency components) should be less than the permissible maximum value of the ac flux density Bac_max_eqa and is given by 𝐡 π‘Žπ‘_max _π‘’π‘žπ‘’ = 𝐡 1π‘šπ‘Žπ‘₯ cos(πœ”π‘‘ + 𝛿 1 ) + 𝐡 2π‘šπ‘Žπ‘₯ cos(2πœ”π‘‘ + 𝛿 2 ) … 𝐡 π‘›π‘šπ‘Žπ‘₯ cos(π‘›πœ”π‘‘ + 𝛿 𝑛 ) (8) where B1max, B2max … Bnmax are the maximum flux densities of voltages at multiple frequency components x=1,2…n respectively.…”
Section: Calculation Of Rated Ac Voltagementioning
confidence: 99%
“…Specifically, with sensitive loads, the detecting system should be fast enough to identify the voltage disturbance accurately for the assessment of DVR performance [20] [45]. As shown in Figure 2, various methods for voltage disturbance detection have been proposed, including RMS, Peak Value, DFT, Fourier Transform (FT), Wavelet Transform (WT), Windowed Fast FT (WFFT), ABC to DQ axis transformation, KF, Phase-Locked Loop (PLL), and SRF [28] [46]. The benefits and drawbacks of the most serious voltage disturbance detection techniques are provided in Table I.…”
Section: B Control Strategies and Algorithms Of Dvrmentioning
confidence: 99%
“…The low inverter losses and reduced harmonic content welcomes the open end winding transformer into the DVR topology [64]. A multilevel inverter based DVR coupled with cascaded open-end winding (OEW) transformer is reported in [65]. However, [2] rules out the need for multilevel structures in FACTS.…”
Section: Topologies Of Dvrmentioning
confidence: 99%