PurposeSilicon photovoltaics technology has drawbacks of high cost and power conversion efficiency. In order to extract the maximum output power of the module, maximum power point (MPP) is used by implying the nonlinear behavior of I-V characteristics. Different techniques are used regarding maximum power point tracking (MPPT). The paper aims to review the techniques of MPPT used in PV systems and review the comparison between Perturb and Observe (P&O) method and incremental conductance (IC) method that are used to track the maximum power and gives a comparative review of all those techniques.Design/methodology/approachA study of MPPT techniques for photovoltaic (PV) systems is presented. Matlab Simulink is used to find the MPP using P&O simulation along with IC simulation at a steady temperature and irradiance.FindingsMATLAB simulations are used to implement the P&O method and IC method, which includes a PV cell connected to an MPPT-controlled boost converter. The simulation results demonstrate the accuracy of the PV model as well as the functional value of the algorithms, which has improved tracking efficiency and dynamic characteristics. P&O solution gave 94% performance when configured. P&O controller has a better time response process. As compared to the P&O method of tracking, the incremental conductance response rate was significantly slower.Originality/valueIn PV systems, MPPT techniques are used to optimize the PV array output power by continuously tracking the MPP under a variety of operating conditions, including cell temperature and irradiation level.
A constant worldwide growing load stress over a power system compelled the practice of a reactive power injection to ensure an efficient power network. For this purpose, multiple technologies exist in the knowledge market out of which this paper emphasizes the usage of the flexible alternating current transmission system (FACTS) and presents a comparative study of the static var compensator (SVC) with the static synchronous compensator (STATCOM), inducted in a real electric substation. The aim is to improve the power factor (PF) and power quality and to encounter reliably extreme conditions. A 220 kV electric substation was opted for the analysis, and both the static and dynamic conditions were observed with the help of a power system analysis tool termed PowerFactory-DIgSILENT. Multiple aspects were investigated via software simulations to assess the performance of the aforementioned FACTS devices, such as the voltage profile evaluation via the load flow analysis method (LFA), the harmonic response via the power quality and harmonic analysis tool, and the short-circuit response via the RMS simulation tool. The outcomes were verified and compared with permissible values included in the universal standards, such as IEC and IEEE. The superiority of the STATCOM over the SVC was proven in light of the simulative results.
This paper introduces a new method to estimate the motor speed based on the Model Reference Adaptive System (MRAS) technique. The novelty of the proposed MRAS control structure relies on using the motor input impedance angle as a reference state variable to estimate the motor speed. In this context, the reference angle is obtained from measuring the angle between the motor terminal voltage and current vectors using a double-structure Phase Locked Loop (PLL). The tunable angle is instantaneously calculated using the per-phase motor equivalent circuit. Having the impedance angle as the only candidate for the proposed scheme inherently decouples the reference and the adaptive models. This decoupling resulted in obtaining a superior performance at low, high, and zero speeds. The simplicity of the reference and the adaptive schemes ease the analysis, design, and implementation. The introduced speed estimation concept is validated under different scenarios of operating conditions.
The synergetic control technique (SCT) has the solution for understanding the symmetry inherent in the non-linear properties of wind turbines (WTs); therefore, they achieve excellent performance and enhance the operation of the WT. Small-scale WTs are efficient and cost-effective; they are usually installed close to where the generated electricity is used. This technology is gaining popularity worldwide for off-grid electricity generation, such as in rural homes, farms, small factories, and commercial properties. To enhance the efficiency of the WT, it is vital to operate the WT at its maximum power. This work proposes an efficient and fast maximum power point tracking (MPPT) technique based on the SCT to eradicate the drawbacks of the conventional methods and enhance the operation of the WT at the MPP regardless of wind speed and load changes. The SCT has advantages, such as robustness, simplified design, fast response, no requirement for knowledge of WT characteristics, no need for wind sensors or intricate power electronics, and straightforward implementation. Furthermore, it improves speed convergence with minimal steady-state oscillations at the MPP. The investigated configuration involves a wind-driven permanent magnet synchronous generator (PMSG), uncontrolled rectifier, boost converter, and variable load. The two converters are used to integrate the PMSG with the load. Three scenarios (step changes in wind speed, stochastic changes in wind speed, and variable electrical load) are studied to assess the SCT. The results prove a high performance of the suggested MPPT control method for a fast convergence speed, boosted WT efficacy, low oscillation levels, and applicability under a variety of environmental situations. This work used the MATLAB/Simulink program and was then implemented on a dSPACE 1104 control board to assess the efficacy of the SCT. Furthermore, experimental validation on a 1 kW Darrieus-type WT driving a PMSG was performed.
Indirect Lightning Stroke (ILS) is considered an urgent issue on overall power systems due to its sudden dangerous occurrence. A grid-connected solar Photovoltaic (PV) power plant of 1MW was considered and analyzed using PSCAD/EMTDC software. The effect of grounding grid resistance (R g ) on the induced voltages caused by the indirect strokes was discussed. The Transient Grounding Potential Rise (TGPR) variation with R g was presented and discussed. Four different models were proposed and installed for the system under study, which includes a combination of the Externally Gapped Line Arrester (EGLA) with the Non-Gapped Line Arrester (NGLA). The results show that when the R g was reduced from 5 to 1 ohm, TGPR decreased by about 79.63%, whereas the peak value was reduced by about 91.3% nearby the striking position. Four models of EGLAs were proposed to reduce the induced transient overvoltage effectively. The four models showed a remarkable ability to reduce the backflow current (BFC) and, consequently, the induced overvoltage. The EGLA's type with the composite air gap reduced the TGPR by about 77.04 % and reduced the induced overvoltage nearby the striking position by about 51.3%.INDEX TERMS ILS, EGLA, NGLA, backflow current (BFC), PV, grounding grid design (GGD), composite insulator, discharge voltage.
Nowadays, power quality under the excessive implementation of power electronics devices is quite challenging issue. The compensation of non-sinusoidal; reactive and harmonic; components is the main role for power quality devices which highly depend on the robustness of the control system. Some common control systems are implemented using DQ theory. This paper proposes a new version of DQ control technique to control dynamic voltage restorer under severe transient voltage conditions. The power system network with the new DQ control technique is studied and analyzed under different scenarios to compensate for severe balanced and unbalanced voltage sags and swells. This new scheme is based on extraction of positive sequence components to implement the control algorithm. A mathematical model of the DVR, hysteresis voltage control, converter controller model, new DQ scheme with complete system equations are carried out and verified using Simulink / MATLAB. The proposed system is validated experimentally using DSpace 1104 based laboratory system. The obtained results of the proposed compensation algorithm are compared with the results obtained from the traditional DQ method. Simulation and experimental results are correlated and show effectiveness of the proposed DQ control scheme.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.