2021
DOI: 10.1186/s12968-021-00722-7
|View full text |Cite
|
Sign up to set email alerts
|

Cardiovascular magnetic resonance and transesophageal echocardiography in patients with prosthetic valve paravalvular leaks: towards an accurate quantification and stratification

Abstract: Background Objective assessment of prosthetic paravalvular leak (PVL) is complex and challenging even in transesophageal echocardiography (TEE). Our aim was to assess the value of cardiovascular magnetic resonance (CMR) in quantifying PVL in aortic (AVR) or mitral valve (MVR) replacement. Methods Thirty-one patients (62 ± 15.1 years, 63% males) with a preliminary diagnosis of significant PVL (AVR, n-23; MVR, n = 8) were recruited. The TEE PVL grad… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 30 publications
0
6
0
Order By: Relevance
“…This approach has applications beyond TAVR. Compared with transesophageal echocardiography (TEE), CMR appears to have higher sensitivity to detect significant periprosthetic regurgitation after both surgical AVR or MVR ( 7 , 8 ). Semiquantitative TEE underestimates a considerable number of AVR or MVR PVL ( 7 ).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This approach has applications beyond TAVR. Compared with transesophageal echocardiography (TEE), CMR appears to have higher sensitivity to detect significant periprosthetic regurgitation after both surgical AVR or MVR ( 7 , 8 ). Semiquantitative TEE underestimates a considerable number of AVR or MVR PVL ( 7 ).…”
Section: Discussionmentioning
confidence: 99%
“…Compared with transesophageal echocardiography (TEE), CMR appears to have higher sensitivity to detect significant periprosthetic regurgitation after both surgical AVR or MVR ( 7 , 8 ). Semiquantitative TEE underestimates a considerable number of AVR or MVR PVL ( 7 ). 4D flow CMR has also been used in a patient to detect a PVL after pulmonary valve replacement, and it was helpful to accurately quantify an effective regurgitant volume for decision making ( 9 ).…”
Section: Discussionmentioning
confidence: 99%
“…This prospective single-center study was performed in the Upper-Silesian Medical Center of the Medical University of Silesia in Katowice. Some of the study patients (within Groups 1 and 3) that were scheduled for CMR were included in our previous papers evaluating distinct aspects of cardiac imaging, which are not related to this study (quantification of paracardial fat depots or quantification of native and paravalvular aortic regurgitations) [ 11 , 12 , 13 ]. This paper presents results that have not been used or published before.…”
Section: Methodsmentioning
confidence: 99%
“…Objective assessment of PVL may be challenging [15] and may require cardiovascular magnetic resonance (CMR) to quantify. However, Transesophageal echo is still the gold standard method for immediate post procedure assessment of heart valve repair or replacement [16]. Additionally, Patients with PVL may remain asymptomatic for long period and can be associated with heart failure, hemolysis and/or endocarditis [17].…”
Section: Paravalvular Leak (Pvl)mentioning
confidence: 99%