Background: In recent years, the use of del Nido cardioplegia, initially intended for paediatric cardiac surgery, has been extended to adult cardiac surgery in many institutions. Our aim was thus to compare the outcomes of the use of del Nido cardioplegia with that of conventional cardioplegia and discuss its role in both adult and paediatric cardiac surgery. Method: A systematic literature search was conducted in August 2019 on Medline (via PubMed), Embase and Cochrane electronic databases according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Any retrospective studies and randomised controlled trials that reported findings comparing the outcomes of the use of del Nido cardioplegia with that of St. Thomas cardioplegia were included. Results: We observed shorter aortic cross-clamp time (mean difference: −15.18, confidence interval: −27.21 to −3.15, p = 0.01) and cardiopulmonary bypass time (mean difference: −13.52, confidence interval: −20.64 to −6.39, p = 0.0002) associated with the use of del Nido cardioplegia in adult cardiac surgery as compared to St. Thomas cardioplegia. Defibrillation rates were significantly lower in patients who had been given del Nido cardioplegia, in both adult (relative risk: 0.28, confidence interval: 0.12 to 0.64, p = 0.003) and paediatric patients (relative risk: 0.25, confidence interval: 0.08 to 0.79, p = 0.02). Conclusion: Del Nido cardioplegia may be a viable alternative to the use of St. Thomas cardioplegia in both adult and paediatric patients, providing similar postoperative outcomes while also affording the additional advantage of shorter aortic cross-clamp time and cardiopulmonary bypass time (in adult cardiac surgery) and decreased rates of defibrillation (in both adult and paediatric cardiac surgery).
Background: The current treatment for aortic stenosis includes open surgical aortic valve replacement (SAVR) as well as endovascular transcatheter aortic valve replacement (TAVR). This study aims to compare the 1-year, 2-3 year and 5-year structural durability of TAVR valves with that of SAVR valves. Method: A systematic literature search was conducted in July 2019 on Medline (via PubMed), Embase and Cochrane electronic databases according to the PRISMA guidelines. Results: Thirteen randomized controlled trials were included. From the meta-analysis, we observed higher rates of 1-year (OR: 7.65, CI: 4.57 to 12.79, p < 0.00001), 2-3-year (OR: 13.49, CI: 5.66 to 32.16, p < 0.00001) and 5-year paravalvular regurgitation (OR: 14.51, CI: 4.47 to 47.09, p < 0.00001) associated with the TAVR valves than the SAVR valves. There were also higher rates of 1-year (
DNA lesions arising from both exogenous and endogenous sources occur frequently in DNA. During DNA replication, the presence of unrepaired DNA damage in the template can arrest replication fork progression, leading to fork collapse, double-strand break formation, and to genome instability. To facilitate completion of replication and prevent the generation of strand breaks, DNA damage tolerance (DDT) pathways play a key role in allowing replication to proceed in the presence of lesions in the template. The two main DDT pathways are translesion synthesis (TLS), which involves the recruitment of specialized TLS polymerases to the site of replication arrest to bypass lesions, and homology-directed damage tolerance, which includes the template switching and fork reversal pathways. With some exceptions, lesion bypass by TLS polymerases is a source of mutagenesis, potentially contributing to the development of cancer. The capacity of TLS polymerases to bypass replication-blocking lesions induced by anti-cancer drugs such as cisplatin can also contribute to tumor chemoresistance. On the other hand, during homology-directed DDT the nascent sister strand is transiently utilised as a template for replication, allowing for error-free lesion bypass. Given the role of DNA damage tolerance pathways in replication, mutagenesis and chemoresistance, a more complete understanding of these pathways can provide avenues for therapeutic exploitation. A number of small molecule inhibitors of TLS polymerase activity have been identified that show synergy with conventional chemotherapeutic agents in killing cancer cells. In this review, we will summarize the major DDT pathways, explore the relationship between damage tolerance and carcinogenesis, and discuss the potential of targeting TLS polymerases as a therapeutic approach.
Background Fractional flow reserve (FFR) is a well‐established method for the evaluation of coronary artery stenosis before percutaneous coronary intervention. However, whether FFR assessment should be routinely used before coronary artery bypass graft surgery (CABG) remains unclear. A meta‐analysis of prospectively randomized controlled trials (PRCTs) was carried out to compare the outcomes of FFR‐guided CABG vs coronary angiography (CAG)‐guided CABG. Method The meta‐analysis adhered to the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses guidelines. Two PRCTs (the FARGO and GRAFFITI trials) were found and included reporting data on 269 patients with 6 and 12 month follow‐up. Primary endpoints were rates of overall death, MACCE, target vessel revascularization, and spontaneous myocardial infarction (MI). Secondary endpoints were overall graft patency and patency of arterial and venous grafts. Results There were no significant differences between the FFR‐guided and CAG‐guided groups in the rates of overall death, MACCE, target vessel revascularization, spontaneous MI and graft patency. Meta‐analysis of FARGO and GRAFFITI PRCTs showed that FFR‐guided CABG and CAG‐guided CABG produced similar clinical outcomes with similar graft patency rates up to a year postoperatively. Conclusion Currently available PRCTs showes no sufficient evidence to support the use FFR in CABG.
Background CORKNOT® facilitates a reduction in cardiopulmonary bypass (CPB) time, aortic cross clamp (ACC) time and operative time, but reported to be associated with other complications. We aim to quantify the incidence of valvular complications related to CORKNOT® and determine the feasibility of its use between different valvular surgeries. Methods Patients who underwent heart valve repair or replacement surgery via the use of automated titanium suture fasteners (CORKNOT®) in a tertiary care hospital were included in the study. This single-centre retrospective study was conducted on 132 patients between January 2016 and June 2018. Results In our study, the overall mean operative time was 320.0 ± 97.0 min, mean CPB time was 171.4 ± 76.0 min and the calculated mean ACC time was 105.9 ± 54.0 min. Fifty-eight patients (43.9%) underwent minimally invasive valve replacement or repair surgery and 66 patients (50.0%) underwent concomitant procedures. A total of 157 valves were operated on, with 112 (84.8%) single valve surgeries, 15 (11.4%) double valve surgeries and 5 (3.8%) triple valve surgeries. After reviewed by the cardiologist blinded towards the study, we report trivial and/or mild paravalvular leak (PVL) in immediate post-operative echocardiography was found in 1 (1.01%) patients. There were no reported cases of valvular thrombosis, leaflet perforation, device dislodgement or embolization, moderate and/or severe PVL during hospitalization and follow-up echocardiography within 1 year. Single mitral valve and aortic surgeries had comparable incidences of post surgical complications. Conclusion We conclude the feasibility of CORKNOT® utilisation in mitral and aortic valve surgeries. Additionally, incidence of CORKNOT® related complications in heart valve repair or replacement surgery is less usual in our setting than previously reported. These results motivate the use of CORKNOT® as a valid alternative with complete commitment.
Background: CORKNOT® facilitates a reduction in cardiopulmonary bypass (CPB) time, aortic cross clamp (ACC) time and operative time, but reported to be associated with other complications. We aim to quantify the incidence of valvular complications related to CORKNOT® and determine the feasibility of its use between different valvular surgeries. Methods: Patients who underwent heart valve repair or replacement surgery via the use of automated titanium suture fasteners (CORKNOT®) in a tertiary care hospital were included in the study. This single-centre retrospective study was conducted on 136 patients between January 2016 and June 2018. Results: In our study, the mean operative time was 320.0 ± 97.0 min, mean CPB time was 171.4 ± 76.0 min and the calculated mean ACC time was 105.9 ± 54.0 min. 58 patients (43.9%) underwent minimally invasive valve replacement or repair surgery and 66 patients (50.0%) underwent concomitant procedures. A total of 157 valves were operated on, with 112 (84.8%) single valve surgeries, 15 (11.4%) double valve surgeries and 5 (3.8%) triple valve surgeries. The incidence of moderate and/or severe paravalvular leak (PVL) in immediate post-operative echocardiography was found in 7 (5.3%) patients. There were no reported cases of valvular thrombosis leaflet perforation, device dislodgement or embolization during follow-up echocardiography. Single mitral valve and aortic surgeries had comparable incidences of valvular complications. Conclusion: We conclude the feasibility of CORKNOT® utilisation in mitral and aortic valve surgeries. Additionally, incidence of CORKNOT® related complications in heart valve repair or replacement surgery is less usual in our setting than previously reported. These results motivate the use of CORKNOT® as a valid alternative with complete commitment.
Objective The COR-KNOT® device is an automated suture fastener in which there is currently no consensus on its role in heart valve surgery. Our aim was thus to conduct a one-to-one comparison of clinical outcomes with a hand-tied control cohort. Methods We performed a single-center, cumulative propensity-matched retrospective cohort study on patients undergoing heart valve surgery from 1 January 2015 to 13 February 2020. Propensity score matching was performed on 693 patients, dividing them into matched COR-KNOT® ( n = 124) and hand-tied ( n = 124) groups. Results Data on baseline demographics, operative details, and clinical outcomes were analyzed and compared between the groups. The patients in both the COR-KNOT® and control groups were well-matched. For the median sternotomy (MS) all procedures subgroup, use of COR-KNOT® was associated with a decrease of around 49 min in CPB time (220.00 [168.00 to 256.00] vs 70.50 [134.00 to 236.75] min, P = 0.006) and around 32 min in ACC time (145.00 [109.00 to 189.00] vs 112.50 [81.00 to 161.75] min, P = 0.008). In the MS valve and CABG subgroup, use of COR-KNOT® was associated with a 70 min reduction in overall operation time (401.00 [354.25 to 468.75] vs 330.50 [288.50 to 370.50] min, P = 0.013), 63 min reduction in CPB time (216.50 [191.75 to 283.25] vs 153.00 [124.75 to 207.50] min, P = 0.004) and 45 min reduction in ACC time (146.00 [134.50 to 205.50] vs 100.50 [71.50 to 150.75] min, P = 0.003). Conclusions In heart valve surgery, use of the automated suture fastener was associated with shorter CPB and ACC times. Additionally, we determined that clinical outcomes are most likely unaffected by the use of COR-KNOT®.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.