2014
DOI: 10.1063/1.4879542
|View full text |Cite
|
Sign up to set email alerts
|

Carbon nanotube microbolometers on suspended silicon nitride via vertical fabrication procedure

Abstract: We report on carbon nanotube membrane microbolometers, operating uncooled in the near-infrared (IR) and mid-IR band, with speed of 10 ms and responsivity of several kV/W. The microbolometers were fabricated using a vertical process on a thin suspended silicon nitride film for thermal isolation. The measured detectivity was $5.5 Â 10 6 cm Hz 1/2 W À1 at 40 Hz. The broadband spectral responses measured at room temperature over the entire band of the IR illumination source are characteristic of bolometric respons… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 10 publications
(2 citation statements)
references
References 13 publications
0
2
0
Order By: Relevance
“…Table 4 lists some of the most important results from 2006 to 2015, in which all device parameters were measured at room temperature. In terms of active materials, we can roughly categorize CNT-based bolometric IR detectors into three groups: i) SWCNT films, [54,82,83,98] ii) SWCNT-polymer composites, [84][85][86][95][96][97] and iii) MWCNT bundles or films. [87-90, 99, 100, 101] Except on some rare occasions, the typical response time of these devices is in the range of tens of milliseconds, and the typical dectectivity is ~10 6 -10 7 cm Hz 1/2 /W with working wavelengths extending from the near IR (~0.94 µm) to long-wavelength IR region (~20 µm).…”
Section: Cnt Bolometersmentioning
confidence: 99%
See 1 more Smart Citation
“…Table 4 lists some of the most important results from 2006 to 2015, in which all device parameters were measured at room temperature. In terms of active materials, we can roughly categorize CNT-based bolometric IR detectors into three groups: i) SWCNT films, [54,82,83,98] ii) SWCNT-polymer composites, [84][85][86][95][96][97] and iii) MWCNT bundles or films. [87-90, 99, 100, 101] Except on some rare occasions, the typical response time of these devices is in the range of tens of milliseconds, and the typical dectectivity is ~10 6 -10 7 cm Hz 1/2 /W with working wavelengths extending from the near IR (~0.94 µm) to long-wavelength IR region (~20 µm).…”
Section: Cnt Bolometersmentioning
confidence: 99%
“…Recent work demonstrated a SWCNT film microbolometer array of 8 × 8 pixels, which were fabricated using a vertical process on a thin silicon nitride film. [83] This uncooled micorbolometer operated in the NIR and the edge of the midwave-IR band with a speed of 10 ms and detectivity of ~ 5.5 × 10 6 cm Hz 1/2 /W.…”
Section: Bolometers Based On Swcnt Filmsmentioning
confidence: 99%