1988
DOI: 10.1021/ac00156a013
|View full text |Cite
|
Sign up to set email alerts
|

Capillary zone electrophoresis-mass spectrometry using an electrospray ionization interface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
200
0

Year Published

1992
1992
2016
2016

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 386 publications
(200 citation statements)
references
References 8 publications
0
200
0
Order By: Relevance
“…The number of analyte ions that are transferred from one region to the next is proportional to the current density (J) at the entrance orifice of the mass spectrometer and the gas flow into the MS at that orifice [13]. Since ESI is typically performed at atmospheric pressure, the efficient transfer of gas phase ions from ambient pressure to high vacuum required for mass spectrometry was recognized as an important sensitivity issue during the technique's infancy [14,15]. Due to the coulombically repulsive nature of an ESI plume and the characteristic losses of skimmer devices, ion transmission from source to detector in ESI-MS has been quoted as being as low as 1 ion transmitted in 10 5 ions created [2,16].…”
mentioning
confidence: 99%
“…The number of analyte ions that are transferred from one region to the next is proportional to the current density (J) at the entrance orifice of the mass spectrometer and the gas flow into the MS at that orifice [13]. Since ESI is typically performed at atmospheric pressure, the efficient transfer of gas phase ions from ambient pressure to high vacuum required for mass spectrometry was recognized as an important sensitivity issue during the technique's infancy [14,15]. Due to the coulombically repulsive nature of an ESI plume and the characteristic losses of skimmer devices, ion transmission from source to detector in ESI-MS has been quoted as being as low as 1 ion transmitted in 10 5 ions created [2,16].…”
mentioning
confidence: 99%
“…The strong response of QAs using ion evaporation is well documented (Smith et al, 1988). Detection limits in the femtogram range have been reported (Conboy et al, 1990).…”
Section: Detection Limits Of P(etap)thmentioning
confidence: 94%
“…(2) The strongly basic QA was included as a group mediating efficient ionization for detecting amino acid derivatives by ion-evaporation MS at a high sensitivity. It has previously been shown that strongly basic groups such as QAs and strongly acidic groups such as sulfates or sulfonates are detectable at low femtomole levels by ion-evaporation MS (Smith et al, 1988;Conboy et al, 1990;Mueck & Henion, 1990 -Liebold, 1989). (4) PETAPITC is polar.…”
Section: Design Of Novel Sequencing Reagentmentioning
confidence: 99%
“…Thus, it is necessary to create stable electrical and physicochemical conditions for the successful formation of ions, and hence, for successful analysis. [18] …”
Section: Introductionmentioning