1992
DOI: 10.1002/pro.5560010404
|View full text |Cite
|
Sign up to set email alerts
|

Design, synthesis, and characterization of a protein sequencing reagent yielding amino acid derivatives with enhanced detectability by mass spectrometry

Abstract: We report the design, chemical synthesis, and structural and functional characterization of a novel reagent for protein sequence analysis by the Edman degradation, yielding amino acid derivatives rapidly detectable at high sensitivity by ion-evaporation mass spectrometry. We demonstrate that the reagent 3-[4'(ethylene-N, N, N-trimethylamino)phenyl]-2-isothiocyanate is chemically stable and shows coupling and cyclization/cleavage yields comparable to phenylisothiocyanate, the standard reagent in chemical sequen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

1993
1993
2023
2023

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 41 publications
(19 citation statements)
references
References 27 publications
0
19
0
Order By: Relevance
“…The second type of system shown is the time-off light (TOF) mass spectrometer, which has the added capability of providing a higher mass resolution spectrum from each component that is assayed. The third system shown is the triple quadruple MS-MS system, which is most often used for bio analytical assays but can also be used for metabolite identification assays 3 . The fourth MS system is called an ion-trap mass spectrometer and has the unique capability of producing MS data that are important when performing structural elucidation assays.…”
Section: Principles Of Lc-msmentioning
confidence: 99%
“…The second type of system shown is the time-off light (TOF) mass spectrometer, which has the added capability of providing a higher mass resolution spectrum from each component that is assayed. The third system shown is the triple quadruple MS-MS system, which is most often used for bio analytical assays but can also be used for metabolite identification assays 3 . The fourth MS system is called an ion-trap mass spectrometer and has the unique capability of producing MS data that are important when performing structural elucidation assays.…”
Section: Principles Of Lc-msmentioning
confidence: 99%
“…To enhance the ionization efficiency, 3-[4'(ethylene-N,N,N-trimethylamino)phenyl]-2-isothiocyanate (PETAPITC; Aebersold et al, 1992) and 4-(3-pyridinylmethylaminocarboxypropyl)phenyl isothiocyanate (PITC 311; Bures et al, 1995) were developed as an Edman reagent. The ladder sequencing by the mass spectrometric detection was reported using PITC containing 5% (v/v) phenylisocyanate (PIC) without the separation of PTH amino acids (Chait et al, 1993).…”
Section: Sequencing and Configuration Determination By Mass Spectrometrymentioning
confidence: 99%
“…Reagent 12 was prepared according to the procedure for phenyl isothiocynate (PITC) [8] from 4amino-benzo-15-crown-5 (Parish Chemical Co., Odem, UT). Tagging of amino acids was carried out in the usual way.…”
Section: Sample Preparationmentioning
confidence: 99%