2001
DOI: 10.1021/ac010692p
|View full text |Cite
|
Sign up to set email alerts
|

Capillary Array Electrophoresis-MALDI Mass Spectrometry Using a Vacuum Deposition Interface

Abstract: We previously introduced a vacuum deposition interface for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF MS) on a moving surface (e.g., quartz wheel, Mylar tape, metal target). In our present work, the approach has been extended to demonstrate parallel analysis for multiple on-line infusion MALDI MS and capillary array electrophoresis (CAE)-MALDI MS. In the infusion mode, individual peptide samples were simultaneously deposited on a Mylar tape cartridge using an array … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
94
0

Year Published

2002
2002
2012
2012

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 89 publications
(94 citation statements)
references
References 44 publications
(60 reference statements)
0
94
0
Order By: Relevance
“…Analysis of the total cell digest has the advantage of minimizing losses of low level proteins, as well as reducing the complexities of the many sample aliquots that can result from approaches such as organelle isolation and gel based studies. In related studies it has been shown that coupling of either ESI [31] or MALDI [32] to a separation system gives a significant increase in the number of peptide or protein identifications. This improved result was attributed to the use of a prefractionation step to minimize the selective ionization of certain solutes that is often observed in direct MS measurements of complex mixtures.…”
Section: Discussionmentioning
confidence: 99%
“…Analysis of the total cell digest has the advantage of minimizing losses of low level proteins, as well as reducing the complexities of the many sample aliquots that can result from approaches such as organelle isolation and gel based studies. In related studies it has been shown that coupling of either ESI [31] or MALDI [32] to a separation system gives a significant increase in the number of peptide or protein identifications. This improved result was attributed to the use of a prefractionation step to minimize the selective ionization of certain solutes that is often observed in direct MS measurements of complex mixtures.…”
Section: Discussionmentioning
confidence: 99%
“…The peptides of the combined calibration mixtures 1 and 2 were dissolved in 20% ACN/0.01% TFA to final concentrations of 125 fmol/ L des-arg 1 -bradykinin, 413 fmol/ L angiotensin I, 163 fmol/ L glu 1 -fibrinopeptide B, 6 fmol/ L neurotensin, 250 fmol/ L ACTH (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17), 188 fmol/ L ACTH (18 -39), 375 fmol/ L ACTH , and 438 fmol/ L bovine insulin. The in-solution BSA digest was dissolved in 30% ACN/0.1% TFA to a final concentration of 1 fmol/ L. p-Methoxybenzylpyridinium chloride, which was used for the measurements of the effective temperatures, was dissolved in 20% ACN to final concentrations of 2 and 4 pmol/ L. The initial velocities were measured from 350 fmol bovine insulin as analyte (c ϭ 700 fmol/ L, V ϭ 0.5 L) dissolved in 20% ACN/0.01% TFA; 0.5 L matrix solution (30% ACN/0.1% TFA, c ϭ 45 mM for SA; 70% ACN/0.1% TFA, c ϭ 30 mM for all other matrices) and 0.5 L analyte solution were mixed directly on a polished steel target and air-dried for standard DD preparation.…”
Section: Sample Preparation and Measurementmentioning
confidence: 99%
“…[67][68][69][70][71][72][73][74][75][76][77][78][79][80][81][82][83] Only these two configurations are covered in this review, although, brief descriptions of the other three are given in the succeeding paragraphs.…”
Section: Ionization Methodsmentioning
confidence: 99%
“…This approach was extended to a capillary array system. 76 Ørsnes et al 67 constructed an interface based on a rotating ball inlet (ROBIN), in which the sample adhering to the surface of the ball is continuously carried past a polymer gasket into the vacuum chamber. Musyimi et al 83 modified this design so that the majority of the ball surface is at atmospheric pressure and easily accessible for sample deposition.…”
Section: ·2 Maldi-time-of-flight(tof)-msmentioning
confidence: 99%