2020
DOI: 10.1038/s41598-020-75696-0
|View full text |Cite
|
Sign up to set email alerts
|

Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging

Abstract: We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available 99mTc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(9 citation statements)
references
References 24 publications
(31 reference statements)
1
8
0
Order By: Relevance
“…The GP-MSA collimator achieved a high sensitivity of 790 cps/MBq, which is comparable with previously reported values for general-purpose mouse type (GP-M) collimators (847 cps/MBq) [ 19 ]. The spatial resolution was 2.5 mm, thereby indicating that the spatial resolution of collimators roughly corresponded to each aperture diameter [ 18 , 19 , 21 , 32 ]. We included relatively low concentrations of 0.1 MBq/mL in our phantom experiments, because the amount of tracer that can be administered as well as the scan duration is limited in a busy in vivo animal experiment set-up with a high throughput.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…The GP-MSA collimator achieved a high sensitivity of 790 cps/MBq, which is comparable with previously reported values for general-purpose mouse type (GP-M) collimators (847 cps/MBq) [ 19 ]. The spatial resolution was 2.5 mm, thereby indicating that the spatial resolution of collimators roughly corresponded to each aperture diameter [ 18 , 19 , 21 , 32 ]. We included relatively low concentrations of 0.1 MBq/mL in our phantom experiments, because the amount of tracer that can be administered as well as the scan duration is limited in a busy in vivo animal experiment set-up with a high throughput.…”
Section: Discussionmentioning
confidence: 99%
“…For example, the short-axis size of a rabbit heart is approximately 20 mm. The size of the cFOV of the collimator for rats is 28 mm [ 18 ], thereby insufficient to visualize any uptake of the rabbit's heart without bed motion. When qualitative evaluation is conducted in SPECT images, ratios of the target to the normal organs such as the blood pool and muscles are often used.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…We have herein studied the performance of the U-SPECT 6 E-class (MILabs, The Netherlands) with two stationary detectors and a multipinhole collimator, which might be changed for different animal sizes and image quality requirements 6 . The most important characteristics of the system, such as sensitivity, spatial resolution and contrast-to-noise ratio, have already been published for a set of collimators and for technetium-99 m ( 99m Tc), the most widely used gamma radioisotope 6 , 7 . However, a complete evaluation including additional collimators as well as results for radiotracers different from 99m Tc has not been published yet.…”
Section: Introductionmentioning
confidence: 99%