2019
DOI: 10.5005/jp-journals-10024-2601
|View full text |Cite
|
Sign up to set email alerts
|

Canal Transportation, Centering Ability, and Dentin Removal after Instrumentation: A Micro-CT Evaluation

Abstract: Aim:The aim of this study is to evaluate and compare root canal transportation, centering ability, and amount of dentin removed after root instrumentation with different rotary and reciprocating systems, using micro-computed tomography (micro-CT). Materials and methods: Forty curved mesial canals of lower molars were selected and divided into four experimental groups (n = 10) according to the system used: protaper next (PTN), wave one gold (WOG), prodesign logic (LOG), and vortex blue (VTX). The roots were sca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 34 publications
0
2
0
Order By: Relevance
“…Yilmaz et al reported no statistically significant differences between the amount of dentin removed by ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland), OneShape (Mi-croMega, Besançon, France), and EdgeFile (Edge Endo, Albuquerque, NM) NiTi alloy endodontic rotary files for the whole canal length (p > 0.05) [23]. Moreover, de Albuquerque et al reported that the Protaper Next, Wave One Gold, Predesign Logic, and Vortex Blue NiTi alloy endodontic systems caused a greater dentin removal at the coronal third (9 mm), decreasing at the apical one (3 mm) [24]. These findings are aligned with the results shown in the present study.…”
Section: Discussionmentioning
confidence: 99%
“…Yilmaz et al reported no statistically significant differences between the amount of dentin removed by ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland), OneShape (Mi-croMega, Besançon, France), and EdgeFile (Edge Endo, Albuquerque, NM) NiTi alloy endodontic rotary files for the whole canal length (p > 0.05) [23]. Moreover, de Albuquerque et al reported that the Protaper Next, Wave One Gold, Predesign Logic, and Vortex Blue NiTi alloy endodontic systems caused a greater dentin removal at the coronal third (9 mm), decreasing at the apical one (3 mm) [24]. These findings are aligned with the results shown in the present study.…”
Section: Discussionmentioning
confidence: 99%
“…[14] Vortex Blue showed signi cantly less dentin removal compared to XP-Shaper, WaveOne Gold, ProTaper Next and ProDesign Logic le system [21,27].…”
Section: Discussionmentioning
confidence: 99%