2011
DOI: 10.1002/jor.21353
|View full text |Cite
|
Sign up to set email alerts
|

Callus patterns in femoral lengthening over an intramedullary nail

Abstract: Our objectives were to evaluate callus patterns seen in femoral lengthening over an intramedullary nail by Li classification regarding shape and type and to predict the result while using the nail to reduce the external fixation period and its complications. Eight hundred digital radiographs of 15 patients with 15 segments of femur shortening who underwent femoral lengthening with a monolateral external fixator over an intramedullary nail were analyzed retrospectively by four observers. Each radiograph was stu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
8
0
11

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 13 publications
(20 citation statements)
references
References 20 publications
0
8
0
11
Order By: Relevance
“…Bone density studies would contribute additional information and could possibly shorten the HI even more and therefore the time the EF is in place based on more precise criteria than those used herein. Finally, we preferred the study of quantifiable radiological measurements to observational criteria such as those proposed by Li et al [32], validated by an interobserver study [33].…”
Section: Discussionmentioning
confidence: 99%
“…Bone density studies would contribute additional information and could possibly shorten the HI even more and therefore the time the EF is in place based on more precise criteria than those used herein. Finally, we preferred the study of quantifiable radiological measurements to observational criteria such as those proposed by Li et al [32], validated by an interobserver study [33].…”
Section: Discussionmentioning
confidence: 99%
“…Регенераты имели преимущественно веретенообразную форму, когда в контрольной группе отмечена как веретенообразная, так и цилиндрическая форма регенератов. Эти данные соответствуют клиническим исследованиям плотности и формы регенератов при УПг [37,38]…”
Section: Discussionunclassified
“…First, the accuracy and reliability of the pixel value ratio is not fully established as an objective tool for measuring bone regeneration. Several objective diagnostic tools for assessment of regenerate bone have been introduced such as dual x-ray absorptiometry [10,23], CT [32,35], and pixel value ratio [12,24,38,45]. Serial evaluation of callus during the distraction phase in leg lengthening using dual x-ray absorptiometry or CT is limited because of repeated radiation exposure and metal interference.…”
Section: Discussionmentioning