2019
DOI: 10.1016/j.enbuild.2019.03.001
|View full text |Cite
|
Sign up to set email alerts
|

Building dynamic thermal model calibration using the Energy House facility at Salford

Abstract: Thermal modelling tools have widely been used in the construction industry at the design stage, either for new 8 build or retrofitting existing buildings, providing data for informed decision-making. The accuracy of thermal models has 9 been subject of much research in recent decades due to the potential large difference between predicted and 'in-use' 10 performance -the so called 'performance gap'. A number of studies suggested that better representation of building 11 physics and operation details in thermal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 14 publications
0
4
0
Order By: Relevance
“…The energy simulation model for Nanning Airport was built using Integrated Environmental Solutions (IESVE 2021) software. 39 The model is shown in Figure 12(a) where the physical model, thermal parameters of the enclosure structure, internal room layout, room data, etc. followed the original design.…”
Section: Methodsmentioning
confidence: 99%
“…The energy simulation model for Nanning Airport was built using Integrated Environmental Solutions (IESVE 2021) software. 39 The model is shown in Figure 12(a) where the physical model, thermal parameters of the enclosure structure, internal room layout, room data, etc. followed the original design.…”
Section: Methodsmentioning
confidence: 99%
“…This present work used the IES-VE (Integrated Environmental Solutions Virtual Environment) software which complies with several national and international standards [68]. Many researchers have proven the efficiency of this software by validating the numerical results against experimental data [69][70][71][72][73].…”
Section: Simulation Methodsmentioning
confidence: 99%
“…Further to the previous research mentioned, Ji, et al [45] uses a model to compare a 1920s' house with the real house built inside the thermal chamber. The house model is developed in Integrated Environment Solutions Virtual Environment (IESVE) and implemented with blocked chimney due to health and safety considerations.…”
Section: Analysis Of Other Modelling By Other Researchersmentioning