2017
DOI: 10.1016/j.jece.2017.05.051
|View full text |Cite
|
Sign up to set email alerts
|

BSA and humic acid separation from aqueous stream using polydopamine coated PVDF ultrafiltration membranes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
24
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 86 publications
(25 citation statements)
references
References 39 publications
1
24
0
Order By: Relevance
“…As another essential assessment of the prepared membranes, the antifouling propensity of the prepared membranes was evaluated by the application of PWP again after back flushing. The results are reported in terms of FRR, which is a good indication of the membrane fouling recovery after backwashing . The results of the FRR for the modified membranes and pristine PVDF membrane before and after UV exposure are shown in Figure .…”
Section: Resultsmentioning
confidence: 99%
“…As another essential assessment of the prepared membranes, the antifouling propensity of the prepared membranes was evaluated by the application of PWP again after back flushing. The results are reported in terms of FRR, which is a good indication of the membrane fouling recovery after backwashing . The results of the FRR for the modified membranes and pristine PVDF membrane before and after UV exposure are shown in Figure .…”
Section: Resultsmentioning
confidence: 99%
“…PDA has been used to modify various polymeric membranes, such as polysulfone, polyethersulfone, polyacrylamide, polyethylene, and polyvinylidene fluoride . They used the same coating method with various PDA concentration, coating time, and pH.…”
Section: Introductionmentioning
confidence: 99%
“…PDA has been used to modify various polymeric membranes, such as polysulfone, [26][27][28] polyethersulfone, 29,30 polyacrylamide, 31 polyethylene, 32,33 and polyvinylidene fluoride. 33,34 They used the same coating method with various PDA concentration, coating time, and pH. In general, the PDA coating was able to increase membrane hydrophilicity as evidenced by water contact angle less than 50°and decrease protein absorption due to the antibacterial properties.…”
Section: Introductionmentioning
confidence: 99%
“…One such approach is to use the specific interaction of adsorbents together with membrane‐enhanced separation for effective removal of drugs from the water. Use of coated polymeric microfiltration (MF) and ultrafiltration (UF) membranes has been very promising for the removal of micropollutants . Fang et al used polydopamine for coating the internal pores of an asymmetric polyethersulfone UF membrane for capturing heavy metals (Pb 2+ , Cd 2+, and Cu 2+ ions) from water.…”
Section: Introductionmentioning
confidence: 99%