2015
DOI: 10.1016/j.ejmp.2015.07.001
|View full text |Cite
|
Sign up to set email alerts
|

Brain PET imaging optimization with time of flight and point spread function modelling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
13
1
2

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 16 publications
(18 citation statements)
references
References 24 publications
(37 reference statements)
2
13
1
2
Order By: Relevance
“…Other radiotracers have been synthetized for glioma assessment (other amino-acid radiotracers like 11 Firstly, regarding static parameters, our results showed that tumor SUVmax and SUVmean obtained with PSF reconstruction were significantly higher than without PSF reconstruction. These results are consistent with data from previous studies assessing the impact of PSF on these parameters (11)(12)(13)(14). Regarding the SUVmean, the results of the current study showed smaller deviations compared to the SUVmax.…”
Section: Discussionsupporting
confidence: 93%
See 2 more Smart Citations
“…Other radiotracers have been synthetized for glioma assessment (other amino-acid radiotracers like 11 Firstly, regarding static parameters, our results showed that tumor SUVmax and SUVmean obtained with PSF reconstruction were significantly higher than without PSF reconstruction. These results are consistent with data from previous studies assessing the impact of PSF on these parameters (11)(12)(13)(14). Regarding the SUVmean, the results of the current study showed smaller deviations compared to the SUVmax.…”
Section: Discussionsupporting
confidence: 93%
“…In our study, the mean percentage change after PSF implementation is considerably lower than in most reports assessing the impact of PSF (12,14,(26)(27)(28). This could be linked to the fact that the current study compared images reconstructed with and without PSF but with TOF algorithm, which already provides higher SUV than SUV obtained with reconstruction using non-TOF algorithm (9,13). The PET images showed essentially low tumors FDOPA uptake in our study.…”
Section: Discussioncontrasting
confidence: 68%
See 1 more Smart Citation
“…5. Dynamic or list-mode acquisition [115,116] To date, the benefit of time-of-flight correction has been modest, but it can be applied [117,118]. 4.…”
Section: Head Stabilitymentioning
confidence: 99%
“…All patients were scanned in a Siemens Biograph mCT TrueV. Acquisition and reconstruction were performed with the standard protocol for brain studies, as previously described [20]. Informed consent was obtained from all individual participants included in the study.…”
Section: Database Analysismentioning