Introduction 3,4-dihydroxy-6-[18F]fluoro-L-phenylalanine (FDOPA) uptake quantification in glioma assessment can be distorted using a non-optimal time frame binning of time-activity curves (TAC). Under-sampling or over-sampling dynamic PET images induces significant variations on kinetic parameters quantification. We aimed to optimize temporal time frame binning for dynamic FDOPA PET imaging. Methods Fourteen patients with 33 tumoral TAC with biopsy-proven gliomas were analysed. The mean SUVmax tumor-to-brain ratio (TBRmax) were compared at 20 min and 35 min postinjection (p.i). Five different time frame samplings within 20 min were compared: 11x10sec-6x15sec-5x20sec-3x300sec; 8x15sec-2x30sec-2x60sec-3x300sec; 6x20sec-8x60sec-2x300sec; 10x30sec-3x300sec and 4x45sec-3x90sec-5x150sec. The reversible singletissue compartment model with blood volume parameter (VB) was selected using the Akaike information criterion. K1 values extracted from 1024 noisy simulated TAC using Monte Carlo method from the 5 different time samplings were compared to a target K1 value as the objective, which is the average of the K1 values extracted from the 33 lesions using an imaging-derived input function for each patient. Results The mean TBRmax was significantly higher at 20 min p.i. than at 35 min p.i (respectively 1.4 +/-0.8 and 1.2 +/-0.6; p <0.001). The target K1 value was 0.161 mL/ccm/min. The 8x15sec-2x30sec-2x60sec-3x300sec time sampling was the optimal time frame binning. K1 values extracted using this optimal time frame binning were significantly different with K1 values extracted from the other time frame samplings, except with K1 values obtained using the 11x10sec-6x15sec-5x20sec-3x300sec time frame binning.
Purpose: The aim of this study was to assess the value of the FDOPA PET kinetic parameters extracted using full kinetic analysis for tumor grading with neuronavigation-guided biopsies as reference in patients with newly-diagnosed gliomas.Methods: Fourteen patients with untreated gliomas were investigated. Twenty minutes of dynamic positron-emission tomography (PET) imaging and a 20-min static image 10 min after injection were reconstructed from a 40-min list-mode acquisition immediately after FDOPA injection. Tumors volume-of-interest (VOI) were generated based on the MRI-guided brain biopsies. Static parameters (TBRmax and TBRmean) and kinetic parameters [K1 and k2 using full kinetic analysis with the reversible single-tissue compartment model with blood volume parameter and the time-to-peak (TTP)] were extracted. Performances of each parameter for differentiating low-grade gliomas (LGG) from high-grade gliomas (HGG) were evaluated by receiver-operating characteristic analyses (area under the curve; AUC).Results: Thirty-two tumoral VOI were analyzed. K1, k2, and TTP were significantly higher for HGG than for LGG (median K1-value = 0.124 vs. 0.074 ml/ccm/min, p = 0.025, median k2-value = 0.093 vs. 0.063 min−1, p = 0.025, and median TTP-value = 10.0 vs. 15.0 min, p = 0.025). No significant difference was observed for the static parameters. The AUC for the kinetic parameters was higher than the AUC for the static parameters (respectively, AUCK1 = 0.787, AUCk2 = 0.785, AUCTTP = 0.775, AUCTBRmax = 0.551, AUCTBRmean = 0.575), significantly compared to TBRmax (respectively, p = 0.001 for K1, p = 0.031 for k2, and p = 0.029 for TTP).Conclusion: The present study suggests an additive value of FDOPA PET/CT kinetic parameters for newly-diagnosed gliomas grading.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.