2021
DOI: 10.1007/s12678-021-00673-8
|View full text |Cite
|
Sign up to set email alerts
|

Bovine Serum Albumin-Dependent Charge-Transfer Kinetics Controls the Electrochemical Immunosensitive Detection: Vibrio cholerae as a Model Bioanalyte

Abstract: Graphical Abstract This work investigates how bovine serum albumin (BSA), a commonly used protein in the fabrication of electrochemical immunosensors, can impact on the sensitivity of detection when integrated with antibody (Ab) pre-encapsulated with (i) insulating polyacrylonitrile (PAN) fibre (i.e., GCE-PAN-Ab-BSA immunosensor) or (ii) conducting PAN-grafted iron (II) phthalocyanine (FePc) (i.e., GCE-PAN@FePc-Ab-BSA immunosensor), using Vibrio cholerae toxin as a case study … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 41 publications
(64 reference statements)
0
4
0
Order By: Relevance
“…The fabrication of the HPV-16 L1 immunosensors and antigen–antibody interaction mechanisms are described in the Experimental Section but summarized as shown in Figure . The HPV antigen or antibody is immobilized onto the OLC- or OLC-PAN electrode via the conventional covalent bonding process through the formation of the strong amide bond using the sulfo-NHS ester. , In practice, route A describes the screening of HPV-16 infection (asymptomatic individuals), while route B is for the testing of the HPV-16 infection (in individual who presents some symptoms).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The fabrication of the HPV-16 L1 immunosensors and antigen–antibody interaction mechanisms are described in the Experimental Section but summarized as shown in Figure . The HPV antigen or antibody is immobilized onto the OLC- or OLC-PAN electrode via the conventional covalent bonding process through the formation of the strong amide bond using the sulfo-NHS ester. , In practice, route A describes the screening of HPV-16 infection (asymptomatic individuals), while route B is for the testing of the HPV-16 infection (in individual who presents some symptoms).…”
Section: Resultsmentioning
confidence: 99%
“…Figure summarizes the fabrication of the sensor. GCE was modified using the drop casting method following a reported method. ,, Briefly, 10 μL of electrocatalyst was drop-casted onto GCE and was dried in an oven at 45 °C for 30 min, and this was labeled as GCE-OLC-PAN . The GCE-OLC-PAN was functionalized with 3 M NaOH for 2 h, the electrode was washed with Millipore water and PBS, after which the functionalized electrode was dried with N 2 gas, to afford a carboxylic acid functionalized surface (GCE-OLC-PAN-COOH).…”
Section: Methodsmentioning
confidence: 99%
“…In 2002, Keller et al reported the first use of OLC as a catalyst for the synthesis of styrene. There are few reports on the use of OLC in electrochemistry, especially in the field of energy storage, but its use in electrocatalysis has rarely been explored. This work shows that OLC is a viable carbon catalyst for tramadol detection compared to the CB counterpart. Preliminary theoretical insights (DFT calculations) predict that the possible reason for the high electrocatalytic performance of the OLC is that the adsorption energy of tramadol onto the surface of OLC is weaker than on the surface of CB.…”
Section: Introductionmentioning
confidence: 92%
“…In addition, human papillomavirus (HPV) is a pathogen of diseases, and high-risk HPV-16 is considered to be responsible for cervical cancer cases. 26 Therefore, the ratiometric ECL biosensor was effectively constructed and combined with DNA recycle amplification reactions to realize ultrasensitive detection of HPV-16 DNA (Scheme 1B). First, Zr-DPA@TCPP deposited on the GCE showed dual emissions at the anode and cathode.…”
Section: ■ Introductionmentioning
confidence: 99%