2021
DOI: 10.2214/ajr.21.25796
|View full text |Cite
|
Sign up to set email alerts
|

Bosniak Classification of Cystic Renal Masses Version 2019: Comparison With Version 2005 for Class Distribution, Diagnostic Performance, and Interreader Agreement Using CT and MRI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
16
0
1

Year Published

2022
2022
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(18 citation statements)
references
References 25 publications
0
16
0
1
Order By: Relevance
“…We also performed subgroup analyses for various examinations involving CT and MRI, both alone and in combination. Regarding the four studies reporting the diagnostic accuracy of CT, the pooled sensitivity and specificity were 0.86 (95% CI 0.68–0.95) and 0.71 (95% CI 0.61–0.80), respectively ( 21 , 23 , 25 , 28 ). For the five studies reporting the diagnostic accuracy of MRI, the pooled sensitivity was comparable (0.87, 95% CI 0.78–0.93) but the specificity was lower (0.67, 95% CI 0.48–0.81) ( 22 , 23 , 25 , 26 , 28 ).…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…We also performed subgroup analyses for various examinations involving CT and MRI, both alone and in combination. Regarding the four studies reporting the diagnostic accuracy of CT, the pooled sensitivity and specificity were 0.86 (95% CI 0.68–0.95) and 0.71 (95% CI 0.61–0.80), respectively ( 21 , 23 , 25 , 28 ). For the five studies reporting the diagnostic accuracy of MRI, the pooled sensitivity was comparable (0.87, 95% CI 0.78–0.93) but the specificity was lower (0.67, 95% CI 0.48–0.81) ( 22 , 23 , 25 , 26 , 28 ).…”
Section: Resultsmentioning
confidence: 99%
“…Regarding the four studies reporting the diagnostic accuracy of CT, the pooled sensitivity and specificity were 0.86 (95% CI 0.68–0.95) and 0.71 (95% CI 0.61–0.80), respectively ( 21 , 23 , 25 , 28 ). For the five studies reporting the diagnostic accuracy of MRI, the pooled sensitivity was comparable (0.87, 95% CI 0.78–0.93) but the specificity was lower (0.67, 95% CI 0.48–0.81) ( 22 , 23 , 25 , 26 , 28 ). Regarding the three studies reporting the diagnostic accuracy of CT in combination with MRI, the pooled sensitivity (0.81, 95% CI 0.70–0.91) was lower than using CT or MRI alone, while the specificity was comparable (0.67, 95% CI 0.61–0.82) ( 21 , 24 , 27 ).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations