2007
DOI: 10.1038/oby.2007.533
|View full text |Cite
|
Sign up to set email alerts
|

Body Composition of Obese Subjects by Air Displacement Plethysmography: The Influence of Hydration

Abstract: Abstract2 ) entered the ADP chamber without and with oil (1, 2, or 4 liters), water (1, 2, or 4 liters), or mixed (1 liter oil ϩ 1 liter water or 2 liters oil ϩ 2 liters water) loads. Real and measured changes in body composition were compared by regression analysis and Bland-Altman procedures. Results: The ADP-measured changes in volume did not differ from the real values and were strongly correlated with them (r ϭ 0.98). In all cases, loads of differing composition and similar volume led to different values … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
2
3

Year Published

2009
2009
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(21 citation statements)
references
References 13 publications
0
16
2
3
Order By: Relevance
“…However, increased hydration of FFM in obesity might lead to an overestimation of FM. If hydration of FFM decreases with weight loss, this would lead to an overestimation of losses in FM [24]. A second limitation of the study was the assumption of a low activity level (PAL 1.5) for 10 patients with missing step count data.…”
Section: Study Limitationsmentioning
confidence: 99%
“…However, increased hydration of FFM in obesity might lead to an overestimation of FM. If hydration of FFM decreases with weight loss, this would lead to an overestimation of losses in FM [24]. A second limitation of the study was the assumption of a low activity level (PAL 1.5) for 10 patients with missing step count data.…”
Section: Study Limitationsmentioning
confidence: 99%
“…Air displacement plethysmography is a new, safe, quick, and valid technique, providing accurate measurements of body density [6] and discriminating moderate changes in FM and FFM [7]. Although some uncertainties due to the hydration of FFM may influence any two-compartment model-based analysis [8], the simultaneous measurement of muscle strength (MS) by dynamometry can be used to confirm the results of FFM: a correlation between FFM and MS has been previously demonstrated [911] …”
Section: Introductionmentioning
confidence: 99%
“…As duas técnicas de avaliação empregadas no presente estudo não se relacionam diretamente pela forma diferente com que mensuram a gordura corporal, entretanto, diversos estudos têm mostrado uma forte correlação entre os resultados (5,7,(22)(23)(24)(25) , trazendo uma alternativa eficiente para o diagnóstico e acompanhamento do excesso de peso relacionado ao acúmulo de tecido adiposo, especialmente em crianças e adolescentes (26) . A pletismografia com deslocamento de ar é outro método para detecção da composição corporal que pode ser considerado fidedigno, rápido (3 a 5 minutos por teste) e de fácil aplicação (28) , por demandar menor necessidade de cooperação do avaliado. Porém, assim como a BIA, pode superestimar a adiposidade em casos de hiperhidratação (1,5,9,28) .…”
Section: Discussionunclassified
“…A pletismografia com deslocamento de ar é outro método para detecção da composição corporal que pode ser considerado fidedigno, rápido (3 a 5 minutos por teste) e de fácil aplicação (28) , por demandar menor necessidade de cooperação do avaliado. Porém, assim como a BIA, pode superestimar a adiposidade em casos de hiperhidratação (1,5,9,28) . Por isso, recomenda-se fortemente que o avaliado siga a padronização do teste (17) e mantenha a ingestão normal de líquidos (boa hidratação) no dia da avaliação.…”
Section: Discussionunclassified