2021
DOI: 10.1016/j.biteb.2021.100846
|View full text |Cite
|
Sign up to set email alerts
|

Biosynthesis of polyhydroxyalkanoate (PHA) by a newly isolated strain Bacillus tequilensis ARY86 using inexpensive carbon source

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 38 publications
0
1
0
Order By: Relevance
“…For example, Jiang et al (2012) reported PHA productivity could reach 2 g/L per day when using paper mill wastewater as a substrate. Mohanrasu et al (2020) also reported a 5.61 g/L production concentration by Bacillus megaterium in a batch culture within 64 h. Yasin and Al-Mayaly (2021) reported that Bacillus tequilensis ARY86 produced PHA with a PHA/CDM ratio of 64% and a PHA concentration of 1.66 g/L using 1% lactose as a carbon source in the medium. Thu et al (2021) reported that Pichia sp.…”
Section: -L Scale Pha Production Processmentioning
confidence: 93%
“…For example, Jiang et al (2012) reported PHA productivity could reach 2 g/L per day when using paper mill wastewater as a substrate. Mohanrasu et al (2020) also reported a 5.61 g/L production concentration by Bacillus megaterium in a batch culture within 64 h. Yasin and Al-Mayaly (2021) reported that Bacillus tequilensis ARY86 produced PHA with a PHA/CDM ratio of 64% and a PHA concentration of 1.66 g/L using 1% lactose as a carbon source in the medium. Thu et al (2021) reported that Pichia sp.…”
Section: -L Scale Pha Production Processmentioning
confidence: 93%
“…Figure 2(C) have similar highest peaks which were at 1008 cm -1 that represented the C-O-C chemical groups of the polymer. The peaks between 1636 cm -1 and 1240 cm -1 were due to the presence of the C=O and C-O compared to the FTIR analysis PHA standard from Yasin and Al-Mayaly (11).…”
Section: Ft-ir Analysis Before and After Sample Extractionmentioning
confidence: 93%
“…Direct FTIR scanning was performed on all samples, both before and after extraction. PHA can be detected using FT-IR spectroscopy (11). For HPLC analysis, the samples were eluted with 5 ml C18 110 column and performed in isocratic mode with water/ACN 70:30 at a flow rate of 0.6 mL/min at 25 °C.…”
Section: Statistical and Analytical Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Afterward, the isothermally crystallized samples were heated again at 1 • C/min. [150,151] X-ray diffraction…”
Section: Crystallinitymentioning
confidence: 99%