2010
DOI: 10.1007/s00604-010-0464-4
|View full text |Cite
|
Sign up to set email alerts
|

Biomimetic norfloxacin sensors made of molecularly-imprinted materials for potentiometric transduction

Abstract: A biomimetic sensor for norfloxacin is presented that is based on host-guest interactions and potentiometric transduction. The artificial host was imprinted into polymers made from methacrylic acid and/or 2-vinyl pyridine. The resulting particles were entrapped in a plasticized poly(vinyl chloride) (PVC) matrix. The sensors exhibit near-Nernstian response in steady state evaluations, and detection limits range from 0.40 to 1.0 μgmL −1 , respectively, and are independent of pH values at between 2 and 6, and 8 a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2012
2012
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(9 citation statements)
references
References 31 publications
0
8
0
Order By: Relevance
“…Where Q is the binding capacity of the polymer in (μM/g), C i is the initial VCV concentration in (μM/mL), C f is the final free VCV concentration at equilibrium in (μM/mL), V s is the volume of sample solution tested (mL) and M is the mass of polymer used in (mg) ; the imprinting factor (IF) was calculated as; trueIF=normalQMIP4pt/normalQNIP …”
Section: Methodsmentioning
confidence: 99%
“…Where Q is the binding capacity of the polymer in (μM/g), C i is the initial VCV concentration in (μM/mL), C f is the final free VCV concentration at equilibrium in (μM/mL), V s is the volume of sample solution tested (mL) and M is the mass of polymer used in (mg) ; the imprinting factor (IF) was calculated as; trueIF=normalQMIP4pt/normalQNIP …”
Section: Methodsmentioning
confidence: 99%
“…The comparison of this work with others (Agrawal et al, 2013;Devaraj, Deivasigamani, Jeyadevan, 2013;Moreira, Freitas, Sales, 2011) showed the advantage of GO added. This research demonstrate again that GO is an excellent modification material in voltammetric sensor.…”
Section: Calibration Curve Stability and Reproducibilitymentioning
confidence: 98%
“…By comparison, electrochemical method is less expensive and has additional advantages, such as fast response speed, simple operation, timesaving, high sensitivity, and real-time detection in clinical and drug control. Based on these reasons, some electrochemical methods for determination of NFX were developed more recently (Agrawal et al, 2013;Devaraj, Deivasigamani, Jeyadevan, 2013;Moreira, Freitas, Sales, 2011). Shim and co-workers (Agrawal et al, 2013) used a multi-walled carbon nanotube (MWCNT) modified pyrolytic graphite (MPG) electrode for determination of NFX.…”
Section: Inroductionmentioning
confidence: 99%
“…Finally, in [288], an approach based on host-guest interaction in molecularly imprinted materials was developed, characterised and successfully applied to the sensing of norflaxin. Polymers were used made from methacrylic acid and/or 2-vinyl pyridine.…”
Section: Potentiometric Sensors Containing New Ion-exchange Componentsmentioning
confidence: 99%