Biomaterials - Physics and Chemistry 2011
DOI: 10.5772/24209
|View full text |Cite
|
Sign up to set email alerts
|

Biomaterials in Urology - Beyond Drug Eluting and Degradable - A Rational Approach to Ureteral Stent Design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 89 publications
0
7
0
1
Order By: Relevance
“…Ureteral stents can be incorporated with drugs and other materials to assist patient comfort and/or to forestall encrustation. Drug-loaded stents liberate medications that perform locally on the bladder to reduce irritation and pain [7,8]. To date, various approaches have been employed in an attempt to do so and have focused on developing novel surface coatings and drug-elution strategies.…”
Section: Discussionmentioning
confidence: 99%
“…Ureteral stents can be incorporated with drugs and other materials to assist patient comfort and/or to forestall encrustation. Drug-loaded stents liberate medications that perform locally on the bladder to reduce irritation and pain [7,8]. To date, various approaches have been employed in an attempt to do so and have focused on developing novel surface coatings and drug-elution strategies.…”
Section: Discussionmentioning
confidence: 99%
“…в 1989 г., который может быть использован у женщин без рент геновского и эндоскопического контроля [13], но стоимость магнитных стентов является немаловажным фактором [14]. Биодеградируемые стенты [15], к сожалению, ввиду слабой управляемости деградации не получили широкого распространения [16]. Стент с нитями [17] -при влекательная опция, но из-за высокой частоты инцидентального выпадения также не являются оптимальным вариантом.…”
Section: Discussionunclassified
“…In these cases, biofilm formation arises due to the deposition of a urinary conditioning film, composed by urinary proteins, ions and crystals at the stent's surface, which favors the interaction and adhesion of bacteria to the stent surface. [12,13] Within biofilm environment, microorganisms are protected from the action of host defenses and antibiotics. [14] In a clinical study, it was found that the most common bacteria found on urinary stent surface biofilms are Escherichia coli, Enterococcus spp.…”
Section: Clinical Needmentioning
confidence: 99%
“…However, this biodegradable design presented higher migration and bacteriuria rates than the ones obtained with the biostable BraidStent. [135] On the other hand, Jin et al 11 and Zhang et al 12 assessed their BUS design in dogs. Jin's stent provided equal drainage as a standard double J ureteral stents and degraded completely by the 5 th week of follow-up, although bulky fragments of the stent were observed during the degradation.…”
Section: Disruption Of Biofilm Architecturementioning