1999
DOI: 10.1002/(sici)1520-6521(1999)3:4/5<307::aid-fact9>3.0.co;2-m
|View full text |Cite
|
Sign up to set email alerts
|

Biological agent detection with the use of an airborne biosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
25
0

Year Published

2001
2001
2012
2012

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 40 publications
(26 citation statements)
references
References 4 publications
0
25
0
Order By: Relevance
“…This method of immobilization has been shown to yield surfaces with improved functionality when compared to surfaces with antibodies immobilized via direct covalent linkage [34,35]. Antibodies were biotinylated using a fivefold molar excess of biotin-LC-NHS ester (Pierce, Rockland, IL, USA).…”
Section: Antibody Preparationmentioning
confidence: 99%
“…This method of immobilization has been shown to yield surfaces with improved functionality when compared to surfaces with antibodies immobilized via direct covalent linkage [34,35]. Antibodies were biotinylated using a fivefold molar excess of biotin-LC-NHS ester (Pierce, Rockland, IL, USA).…”
Section: Antibody Preparationmentioning
confidence: 99%
“…Previous research has shown the value of manned and unmanned systems for aerobiological sampling (Anderson et al, 1999;Corrigan, Roberts, Ramana, Kim, & Ramanathan, 2008;Dingus, 2008;Ingold, 1939;Peräjärvi, Lehtinen, Pöllänen, & Toivonen, 2008;Schmale, Dingus, & Reinholtz, 2008;Techy, Schmale, & Woolsey, 2010;Techy, Woolsey, & Schmale, 2008). Dynamic sampling systems have the potential to improve upon current static, groundbased sampling methods.…”
Section: Introductionmentioning
confidence: 99%
“…Thus it cannot illustrate a multiple sampling as a function of time in different geographic areas. In other research, Anderson et al (1999) used a multichannel fluorimeter and a custom ram-air-driven cyclone particle collector for air sampling experiments. Purified polycyclonal rabbit antibodies were fluoresced using fluorescent dye and dispersed in a predefined test area.…”
Section: Introductionmentioning
confidence: 99%
“…Rowe-Taitt et al detected B. anthracis, F. tularensis, B. abortus with NRL array biosensor in 2000 [17]. Anderson et al investigated B. globigii with Analyte 2000 biosensor in 1999 [6], and then continued to detect B. anthracis, S. typhimurium, Giardia, F. tularensis with biosensor RAPTOR in recent years [1,5,7,8]. Cao et al detected Y. pestis antigen FI and analyzed it in serum, whole blood and plasma and obtained accuracy for determining antigen concentrations from 50 to 400 ng/ml with a fiber optic biosensor in 1995 [11].…”
Section: Introductionmentioning
confidence: 99%