2014
DOI: 10.1053/j.ajkd.2014.01.420
|View full text |Cite
|
Sign up to set email alerts
|

Bioimpedance-Guided Fluid Management in Maintenance Hemodialysis: A Pilot Randomized Controlled Trial

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
241
0
4

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 215 publications
(247 citation statements)
references
References 20 publications
2
241
0
4
Order By: Relevance
“…There is recent randomized trial evidence in hemodialysis patients showing that fluid management guided by a bioimpedance device that provides an estimate of the degree of overhydration may be associated with a reduction in left ventricular hypertrophy and an improvement in blood pressure control and pulse wave velocity (7). Another randomized controlled study also showed an improvement in patient survival (8). However, similar evidence of bioimpedance or guided fluid management is completely lacking in PD patients.…”
Section: No 4 Part I -Management Of Various Cardiovascular Complicmentioning
confidence: 97%
“…There is recent randomized trial evidence in hemodialysis patients showing that fluid management guided by a bioimpedance device that provides an estimate of the degree of overhydration may be associated with a reduction in left ventricular hypertrophy and an improvement in blood pressure control and pulse wave velocity (7). Another randomized controlled study also showed an improvement in patient survival (8). However, similar evidence of bioimpedance or guided fluid management is completely lacking in PD patients.…”
Section: No 4 Part I -Management Of Various Cardiovascular Complicmentioning
confidence: 97%
“…Bioelectrical impedance analysis (BIA) is a method of assessing ECF status by measuring the impedance of the body to applied electric currents of different frequencies 9, 10. Accumulating evidence suggests that strict BIA‐guided fluid management has a beneficial impact on blood pressure, arterial stiffness, left ventricular hypertrophy, and survival in patients undergoing dialysis 11, 12…”
Section: Introductionmentioning
confidence: 99%
“…1,2 Bioimpedance is considered to be a sensitive tool for measuring body fluid composition; however, the interpretation of this data is difficult. The raw impedance data, consisting of resistance and reactance values, are abstract, and provide only indirect information on extraand intracellular fluid volumes.…”
mentioning
confidence: 99%