2017
DOI: 10.1186/s12880-017-0187-7
|View full text |Cite
|
Sign up to set email alerts
|

Biodegradable magnesium Herbert screw – image quality and artifacts with radiography, CT and MRI

Abstract: BackgroundMagnesium alloys have recently been rediscovered as biodegradable implants in musculoskeletal surgery. This study is an ex-vivo trial to evaluate the imaging characteristics of magnesium implants in different imaging modalities as compared to conventional metallic implants.MethodsA CE-approved magnesium Herbert screw (MAGNEZIX®) and a titanium screw of the same dimensions (3.2x20 mm) were imaged using different modalities: digital radiography (DX), multidetector computed tomography (MDCT), high resol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
41
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 52 publications
(48 citation statements)
references
References 29 publications
2
41
0
1
Order By: Relevance
“…Even though magnetic implants are usually avoided to be scanned under MRI, an Fe stent implanted in rabbit abdominal aorta was successfully imaged by this instrument despite the presence of artifacts (Figure 5c) [22]. However, it was shown that MRI has a modality to image tissueimplant interaction in better quality for absorbable Mg alloys, i.e., less artifacts, compared to that of inert metals such as titanium [65]. More recent diagnostic instruments used to assess the in-vivo corrosion of absorbable metals are Micro-Computed Tomography (µCT) and Magnetic Resonance Imaging (MRI).…”
Section: Ultrasonography and Radiographymentioning
confidence: 99%
“…Even though magnetic implants are usually avoided to be scanned under MRI, an Fe stent implanted in rabbit abdominal aorta was successfully imaged by this instrument despite the presence of artifacts (Figure 5c) [22]. However, it was shown that MRI has a modality to image tissueimplant interaction in better quality for absorbable Mg alloys, i.e., less artifacts, compared to that of inert metals such as titanium [65]. More recent diagnostic instruments used to assess the in-vivo corrosion of absorbable metals are Micro-Computed Tomography (µCT) and Magnetic Resonance Imaging (MRI).…”
Section: Ultrasonography and Radiographymentioning
confidence: 99%
“…Moreover, the released appropriate Mg ions could regulate signaling pathways of bone marrow stromal cells and stimulate new bone formation 2 . Clinically, a prospective study of MAGNEZIX ® Mg screws (Syntellix AG, Hannover, Germany) demonstrated that they functioned equivalently to titanium screws during the slight hallux valgus deformities healing 3 . However, rapid and continuous degradation may reduce the mechanical integrity and support properties of Mg implants.…”
Section: Introductionmentioning
confidence: 99%
“…Artifacts will be measured as described by Sonnow et al [15] to evaluate changes of artifact appearance over time. In detail, all artifacts will be assessed in an axial plane or reconstruction of the screw.…”
Section: Methodsmentioning
confidence: 99%
“…Furthermore, magnesium-based implants produce almost no artifacts in MRI or CT even when imaging was done immediately after implantation [9, 15]. In contrast, titanium screws generally create interference.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation