2013
DOI: 10.1007/s10517-013-1973-z
|View full text |Cite
|
Sign up to set email alerts
|

Biochemistry of Blood Plasma and Some Parameters of Antioxidant Status in Rats with Polyhypovitaminosis of Varying Severity

Abstract: In rats with profound vitamin deficiency, blood plasma level of triglycerides significantly decreased by 1.6 times, potassium ions by 5%, uric acid by 23%, ALT and AST by 1.4 times, while the levels of glucose increased by 32%, iron by 31%, urea by 58%, and alkaline phosphatase by 19%. Plasma level of phosphorus tended to decrease and ionized calcium concentration tended to increase. Severe deficiency of all vitamins is accompanied by pronounced accumulation of MDA in the plasma and liver together with simulta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 9 publications
0
2
0
Order By: Relevance
“…The blood samples collected in EDTA bottles were centrifuged for 15 min at 3000 rpm to obtain plasma for biochemical analyses [ 82 , 84 , 85 , 87 , 88 , 89 , 90 ]. The plasma was further analysed for urea, creatinine, creatinine kinase (CK), total protein (TP), albumin (ALB), aspartate aminotransferase (AST) and alanine aminotransferase (ALT) using a fully automated clinical chemistry analyser (BioLis 24i Chemistry Analyzer, Tokyo, Japan) [ 7 , 84 , 86 ].…”
Section: Methodsmentioning
confidence: 99%
“…The blood samples collected in EDTA bottles were centrifuged for 15 min at 3000 rpm to obtain plasma for biochemical analyses [ 82 , 84 , 85 , 87 , 88 , 89 , 90 ]. The plasma was further analysed for urea, creatinine, creatinine kinase (CK), total protein (TP), albumin (ALB), aspartate aminotransferase (AST) and alanine aminotransferase (ALT) using a fully automated clinical chemistry analyser (BioLis 24i Chemistry Analyzer, Tokyo, Japan) [ 7 , 84 , 86 ].…”
Section: Methodsmentioning
confidence: 99%
“…Plasma sample was obtained by centrifuging the anti-coagulated blood samples collected at 3000 rpm for 15 min for blood biochemical analyses [24][25][26][29][30][31][32] . The plasma was subsequently analysed using fully automated clinical chemistry analyser (BioLis 24i Chemistry Analyzer, Japan) for the concentration of urea, creatinine, Alanine Aminotransferase (ALT), Aspartate Aminotransferase (AST), Creatinine Kinase (CK), Total Protein (TP), Albumin (ALB) [10,24] .…”
Section: Clinical Biochemistry Analysismentioning
confidence: 99%