2017
DOI: 10.1016/j.dld.2017.04.007
|View full text |Cite
|
Sign up to set email alerts
|

Biliary plastic stent does not influence the accuracy of endoscopic ultrasound-guided sampling of pancreatic head masses performed with core biopsy needles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
29
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 15 publications
(29 citation statements)
references
References 25 publications
0
29
0
Order By: Relevance
“…In a meta‐analysis of 33 studies including 4984 patients with solid pancreatic neoplasms, EUS‐FNA had a pooled sensitivity of 85% (95% CI 84%‐86%), and a pooled specificity of 98% (95% CI 97%‐99%) for diagnosing malignancies . Additionally, the diagnostic yield of EUS‐guided sampling for pancreatic head lesion does not appeared to be affected by existed biliary stents . In a retrospective cohort study, a total of 677 patients with solid pancreatic head or uncinate lesions and previous biliary stenting underwent evaluation with EUS‐FNA.…”
Section: Resultsmentioning
confidence: 99%
“…In a meta‐analysis of 33 studies including 4984 patients with solid pancreatic neoplasms, EUS‐FNA had a pooled sensitivity of 85% (95% CI 84%‐86%), and a pooled specificity of 98% (95% CI 97%‐99%) for diagnosing malignancies . Additionally, the diagnostic yield of EUS‐guided sampling for pancreatic head lesion does not appeared to be affected by existed biliary stents . In a retrospective cohort study, a total of 677 patients with solid pancreatic head or uncinate lesions and previous biliary stenting underwent evaluation with EUS‐FNA.…”
Section: Resultsmentioning
confidence: 99%
“…As in the Fisher study [11], only FNA was used and suspicious cytology was classified as a true positive. Recently, Antonini et al [9] reported on a study investigating the effect of the presence of plastic stents on sampling with reverse-bevel needles in a cohort of 130 patients (74 without and 56 with a stent); ROSE was available for 23 % of the procedures. Adequacy of tissue was defined as a tissue specimen suitable for cytological examination.…”
Section: Discussionmentioning
confidence: 99%
“…[ 37 ] A contradicting, retrospective study, determined the presence of biliary stent does not influence the tissue sampling adequacy and accuracy of pancreatic head masses performed with core biopsies (FNB). [ 38 ] A combined approach of EUS and ERCP with biliary stenting, under the same sedation, yielded a 25 min increase in procedure length when compared to separate procedures but similar high yields for diagnostic EUS. A trend toward lower biliary stent placement success rates with combined EUS/ERCP was noted but nonsignificant.…”
Section: When Bile Duct Obstruction Is Present Should Eus Be Systemamentioning
confidence: 99%