2011
DOI: 10.1302/0301-620x.93b7.26208
|View full text |Cite
|
Sign up to set email alerts
|

Bicruciate-stabilised total knee replacements produce more normal sagittal plane kinematics than posterior-stabilised designs

Abstract: Bicruciate-stabilised total knee replacement (TKR) aims to restore normal kinematics by replicating the function of both cruciate ligaments. We performed a prospective, randomised controlled trial in which bicruciate- and posterior-stabilised TKRs were implanted in 13 and 15 osteo-arthritic knees, respectively. The mean age of the bicruciate-stabilised group was 63.9 years (SD 10.00) and that of the posterior-stabilised group 63.2 years (SD 6.7). A control group comprised 14 normal subjects with a mean age of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
24
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(26 citation statements)
references
References 31 publications
2
24
0
Order By: Relevance
“…Ward et al 4 investigated the same systems as those in the present study and found no clinical differences between the groups. A fluoroscopic evaluation of the bicruciate substituting system showed KSS values similar to those in the present study 2 .…”
Section: Discussionsupporting
confidence: 59%
See 2 more Smart Citations
“…Ward et al 4 investigated the same systems as those in the present study and found no clinical differences between the groups. A fluoroscopic evaluation of the bicruciate substituting system showed KSS values similar to those in the present study 2 .…”
Section: Discussionsupporting
confidence: 59%
“…It is hypothesized that the added mechanical constraints should guide the motion of the knee during flexion and extension. The in vivo kinematics and kinetics of the guided-motion design were close to normal [1][2][3][4] and fluoroscopy studies have shown that the anterior and posterior cam-post mechanisms were effective in restoring normal knee kinematic patterns 3,4 . Furthermore, the patella-tendon angle approximated normal values at full knee extension, in comparison with that in the conventional posterior stabilized design 4 .…”
mentioning
confidence: 70%
See 1 more Smart Citation
“…Fifteen patients (Table ) affected by primary knee osteoarthritis were implanted with a post‐cam fixed‐bearing prosthesis (Journey® Bi‐Cruciate Stabilized Knee System; Smith & Nephew, Inc, Memphis, TN). This design claims a better restoration of natural knee kinematics by means of a larger constraining effect, implied by the new post‐cam mechanism and by the original shapes of the medial and lateral condyles . At 6 months after surgery, all patients were evaluated clinically and by 3D video‐fluoroscopy in order to derive joint motion at the replaced knee.…”
Section: Methodsmentioning
confidence: 99%
“…Sacrifice of the ACL can result in abnormal kinematics. BCR implants have shown a more physiologic anterior femorotibial contact point and a greater posterior translation in motion compared to ACL-sacrificing implants [7][8][9][10][11]. Recently, Peersman et al [8] showed that changes by removal of the conforming meniscus and cartilage have more impact on tibiofemoral kinematics than different inlay sizes of a BCR TKA.…”
Section: Technical Evolution and Knee Kinematicsmentioning
confidence: 99%