2023
DOI: 10.1016/j.jpowsour.2022.232345
|View full text |Cite
|
Sign up to set email alerts
|

Beware of cyclic voltammetry! Measurement artefact in accelerated stress test of fuel cell cathode revealed by operando X-ray diffraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(13 citation statements)
references
References 32 publications
0
6
0
Order By: Relevance
“…Recently, Chattot et al investigated the effect of potential cycling to low potential after the application of an accelerated stress test protocol. Their results demonstrate that the observed agglomeration of catalyst particles is induced by cycling to low potential rather than a consequence of the performed stress protocol [63]. Therefore, special care has to be taken, when ECSA methods are performed after or in between stress tests.…”
Section: Which Methods Should Be Chosen For Ecsa Determination?mentioning
confidence: 97%
“…Recently, Chattot et al investigated the effect of potential cycling to low potential after the application of an accelerated stress test protocol. Their results demonstrate that the observed agglomeration of catalyst particles is induced by cycling to low potential rather than a consequence of the performed stress protocol [63]. Therefore, special care has to be taken, when ECSA methods are performed after or in between stress tests.…”
Section: Which Methods Should Be Chosen For Ecsa Determination?mentioning
confidence: 97%
“…Beyond the oxidation-dependent size dynamics, WAXS has also been extensively used to investigate the long-term stability of Pt-based catalysts in the environment of electrochemical cells. Taking the nanoparticles’ coherent domain size increase as an indicator of catalyst degradation, the influence of the catalyst support material chemistry such as doped metal oxides or carbon functionalization, , the initial particles ’size distribution, , the liquid vs solid electrolyte, the upper potential limit during accelerated cycling, or the post-mortem cyclic voltammetry experiment on the material stability were investigated by means of in situ WAXS.…”
Section: Electrocatalysismentioning
confidence: 99%
“…Furthermore, Chattot et al also characterized in operando the anomalous aging of the Pt catalyst after accelerated stress test (AST). 462 the AST's low potential limit, which removes the surface oxygen from oxophilic sites and causes sintering of the catalyst particles and increase of the electrochemical surface area. These findings are only obtainable by performing operando measurements in industrially relevant, high-performance devices.…”
Section: Electrocatalytic Devicesmentioning
confidence: 99%
See 1 more Smart Citation
“…[92] It has e.g been shown that CVs performed after the completion of a typical AST of a PEMFC cause a more coherent domain size increase in the Pt catalyst than the AST itself. [93] This measurement-induced artifact can lead to misinterpretations of catalyst performance, which appears to be less stable. One should carefully choose the operational window in both oxidating and reducing potential windows, as both oxidation and reduction can induce structural changes in the catalyst.…”
Section: Mitigating Radiation Damagementioning
confidence: 99%