2017
DOI: 10.1016/j.compstruct.2017.06.051
|View full text |Cite
|
Sign up to set email alerts
|

Bending behaviour of novel Textile Reinforced Concrete-foamed concrete (TRC-FC) sandwich elements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 71 publications
(21 citation statements)
references
References 9 publications
0
19
0
Order By: Relevance
“…For the four-point bending test, the samples are molded in the rectangular form with the dimensions of 400 × 100 × 15 mm 3 . Basalt textile was used as reinforced with geopolymer mortar matrix, and the specimens were manufactured by hand lay-up method.…”
Section: Specimen Preparationmentioning
confidence: 99%
See 2 more Smart Citations
“…For the four-point bending test, the samples are molded in the rectangular form with the dimensions of 400 × 100 × 15 mm 3 . Basalt textile was used as reinforced with geopolymer mortar matrix, and the specimens were manufactured by hand lay-up method.…”
Section: Specimen Preparationmentioning
confidence: 99%
“…Figure 5 provides the information about the development of the mechanical strength of geopolymer mortar at the various periods of aging time. Three samples with dimension 30 × 30 × 150 mm 3 for each ageing time were used for flexural test, and then the compressive strength was measured on both residual pieces obtained from flexural strength according to EN 196-1 standard [49]. It should be noted that the 28 day specimens were named as a reference sample.…”
Section: Four-point Bending Testmentioning
confidence: 99%
See 1 more Smart Citation
“…The combination of a cementitious matrix with a textile reinforcement has been widely investigated for different kinds of applications: reinforcing and/or strengthening of concrete and masonry structures [2][3][4][5], construction of pedestrian bridges [6], and as skins for the fabrication of sandwich panels. In addition to an experimental characterization of the bending behaviour of TRC sandwich panels [7][8][9][10], various work has been done on the analytical [11,12] and numerical [13][14][15] modelling of this behavior. Textile reinforced cementitious composite (TRC) is characterized by a linear behavior in compression and a non-linear behavior in tension.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the concrete structural elements will become slender, lighter, and more flexible. Textile-reinforced concrete can be utilized in a wide range of applications, such as the lightweight concrete systems [32][33][34], repairing and/or strengthening in current structural elements [35,36], thin wall elements [37,38], etc. In another context, the research and development of non-corrosion textile material, reinforced in Portland cement concrete for the different applications, have been studied by many researchers, however, with respect to the geopolymer, this is quite a new field.…”
Section: Introductionmentioning
confidence: 99%