2008
DOI: 10.1103/physrevstab.11.094201
|View full text |Cite
|
Sign up to set email alerts
|

Benchmarking of measurement and simulation of transverse rms-emittance growth

Abstract: Transverse emittance growth along the Alvarez drift tube linac (DTL) section is a major concern with respect to the preservation of beam quality of high current beams at the GSI UNILAC. In order to define measures to reduce this growth, appropriate tools to simulate the beam dynamics are indispensable. This paper is about the benchmarking of three beam dynamics simulation codes, i.e. DYNAMION, PARMILA, and PARTRAN against systematic measurements of beam emittances for different transverse phase advances along … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
15
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 31 publications
(15 citation statements)
references
References 4 publications
(1 reference statement)
0
15
0
Order By: Relevance
“…For instance, x ¼ 90 corresponds to x;o ¼ 109:4 and y ¼ 90 to y;o ¼ 105:6 . Simulations were done for the real UNILAC machine lattice and the same realistic 7.1 emA 40 Ar þ10 beam with 199 K macroparticles used for the previous benchmarking effort [14]. This input beam was obtained by reconstructing from the emittance measurement conducted before the UNILAC Tank 1.…”
Section: Proposal To Measure the Resonance Stop Band Using Gsi Unmentioning
confidence: 99%
“…For instance, x ¼ 90 corresponds to x;o ¼ 109:4 and y ¼ 90 to y;o ¼ 105:6 . Simulations were done for the real UNILAC machine lattice and the same realistic 7.1 emA 40 Ar þ10 beam with 199 K macroparticles used for the previous benchmarking effort [14]. This input beam was obtained by reconstructing from the emittance measurement conducted before the UNILAC Tank 1.…”
Section: Proposal To Measure the Resonance Stop Band Using Gsi Unmentioning
confidence: 99%
“…An important condition enabling the current study has been the successful termination of a benchmarking experiment at the UNILAC supported by the European Commission [9] in the years 2006-2008, which led to a visible improvement in mismatch control and confidence in diagnostics [10]. In the course of this benchmarking simulations it turned out that at the UNILAC a measurement of the 4th-order resonance might be feasible [11].…”
mentioning
confidence: 99%
“…In order to provide for a 6d-matched injection into the periodically focusing DTL lattice, the setting of the matching section was adapted to each 0 individually. The matching procedure is described in detail in [10]. 0 was varied from 60 to 130 , and for each value of 0 horizontal and vertical phase space distributions were measured at the DTL exit.…”
mentioning
confidence: 99%
“…[mrad] more complex beam lines even with strong space charge [20,21]. The beam moments at the doublet entrance also can be measured if a pepper-pot device will be installed right behind the last singulet.…”
Section: Beams To Be Strippedmentioning
confidence: 99%
“…: ¼ cosðKLÞ; S : ¼ sinðKLÞ;: ¼ 2KL;(20) K from Eq (16),. and L as distance from the effective longitudinal field edge to the foil.…”
mentioning
confidence: 99%