2020
DOI: 10.1088/1748-0221/15/07/p07020
|View full text |Cite
|
Sign up to set email alerts
|

Beam quality and beam loss predictions with space charge for SIS100

Abstract: The SIS100 synchrotron as a part of the new FAIR accelerator facility at GSI should be operated at the "space charge limit" for light and heavy-ion beams. Losses due to space charge induced resonance crossing should not exceed a few percent during a full cycle. Detailed magnet field measurements are now available for 72 out of the total 108 main SIS100 dipole magnets. Particle tracking studies including nonlinear field errors up to 7 th order in the main magnets together with different space charge models are … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 17 publications
(20 reference statements)
0
9
0
Order By: Relevance
“…Contrary to the static field maps in FFSC, the adaptive model picks up and amplifies the macro-particle noise through the field updates. While it is possible to suppress the macroparticle noise impact in the AFSC by choosing larger numbers of macro-particles, relative convergence has only been observed with high numerical resolutions of up to 50 times more macro-particles than FFSC [28]. Despite the suppressed noise effect, the AFSC results still exhibit a systematic overshoot in the predicted rms emittance growth compared to PIC and FFSC around the upper edge of the stop-band.…”
Section: Appendix A: Comment On the Adaptive Frozen Space Charge Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…Contrary to the static field maps in FFSC, the adaptive model picks up and amplifies the macro-particle noise through the field updates. While it is possible to suppress the macroparticle noise impact in the AFSC by choosing larger numbers of macro-particles, relative convergence has only been observed with high numerical resolutions of up to 50 times more macro-particles than FFSC [28]. Despite the suppressed noise effect, the AFSC results still exhibit a systematic overshoot in the predicted rms emittance growth compared to PIC and FFSC around the upper edge of the stop-band.…”
Section: Appendix A: Comment On the Adaptive Frozen Space Charge Modelmentioning
confidence: 99%
“…The stochastic field error model considered in the simulations is based on cold bench measurements and has been described in detail in Ref. [28]. A summarising overview is found in Appendix B.…”
Section: Beam Loss Due To Magnet Field Errorsmentioning
confidence: 99%
See 1 more Smart Citation
“…The nonlinear part has been described in detail in Ref. [2,Section 2]. Beam simulations demonstrate that the multipole errors beyond dodecapolar order b 6 (with figures around or below 0.5 units) have no effect on the losses with space charge during accumulation of heavy ions.…”
Section: First-of-series Quadrupole Unit #2mentioning
confidence: 99%
“…b 3 = 0.7 (not 0.6), b 5 = 1.0 (not 0.9), a 3 = 1.2 (not 0.5) and a 6 = 1.0 (not 0.8). 2 The measurement protocols of the 10 cold quadrupole units bear the CIDs 02000090630, 02000090647, 02000090654, 02000090661, 02000090678, 02000091330, 02000091354, 02000091361, 02000091378, 02000091385 in the respectively tagged reports prepared by JINR Institute, Dubna. • a halved normal octupolar component (≈ factor 0.6),…”
Section: Ensemble Of Series Quadrupole Unitsmentioning
confidence: 99%