Beam image-shift accelerated data acquisition for near-atomic resolution single-particle cryo-electron tomography

Abstract: Tomographic reconstruction of cryopreserved specimens imaged in an electron microscope followed by extraction and averaging of sub-volumes has been successfully used to derive atomic models of macromolecules in their biological environment. Eliminating biochemical isolation steps required by other techniques, this method opens up the cell to in-situ structural studies. However, the need to compensate for errors in targeting introduced during mechanical navigation of the specimen significantly slows down tomogr… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
54
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 72 publications
(55 citation statements)
references
References 39 publications
1
54
0
Order By: Relevance
“…Our data (Supplementary Fig. 5d) support a common observation that rotation of the inplane image shift deviates significantly from the designated coordinates as the stage tilt increases 23 . This departure in image shift values introduced by global tile rotation was much larger than the applied translation alone at lower tilts and became particularly irregular as the stage was tilted to degrees greater than ±30°.…”
supporting
confidence: 87%
See 1 more Smart Citation
“…Our data (Supplementary Fig. 5d) support a common observation that rotation of the inplane image shift deviates significantly from the designated coordinates as the stage tilt increases 23 . This departure in image shift values introduced by global tile rotation was much larger than the applied translation alone at lower tilts and became particularly irregular as the stage was tilted to degrees greater than ±30°.…”
supporting
confidence: 87%
“…9c). We used CTFFIND4 for tilted defocus determination 23 . CTFFIND4 reported the high-resolution limit of detected Thon rings that ranged from 8 to 20 Å for individual tiles and stitched montages at 0° tilt and high tilts (Supplementary Fig.…”
mentioning
confidence: 99%
“…With these requirements, dispersed molecular complexes fare better, because blotting parameters can be adjusted to create ice as thin as possible. In vitro samples like this have achieved sub 5Å resolution, either as part of assemblies [32,33] or as single copies [34,35] (see Figure 3). The latter is as close to the resolution of the same (~300 kDa) particle as solved with SPA.…”
Section: Sample Preparation In Cryoetmentioning
confidence: 99%
“…In recent years, substantial developments in cryo-ET data acquisition and STA processing have resulted in high-resolution structures of challenging samples that are not accessible by any other method (Bäuerlein and Baumeister, 2021). However, while highresolutions at ~4Å can now be reached for some specimens, such as ribosomes (O'Reilly et al, 2020;Tegunov et al, 2021), selected virus assemblies (Dick et al, 2020;Schur et al, 2016), and apoferritin or dNTPase in vitro (Bouvette et al, 2021;Tegunov et al, 2021), the average resolution of cryo-ET-derived structures in the electron microscopy databank (EMDB) has only marginally increased over the last few years (with an average resolution of ~21 Å in 2021) and has remained behind what is now commonly achieved in single-particle particle (SPA) cryo-EM (~5.3 Å average resolution in 2021).…”
Section: Introductionmentioning
confidence: 99%
“…Of the above-mentioned limitations, the last point has recently been addressed in several developments that exploit efficient data acquisition methods, more stable stages and faster cameras (Bouvette et al, 2021;Chreifi et al, 2019;Eisenstein et al, 2019). This has allowed obtaining datasets of hundreds of tomograms within a short time.…”
Section: Introductionmentioning
confidence: 99%