1980
DOI: 10.1088/0031-8949/21/1/005
|View full text |Cite
|
Sign up to set email alerts
|

Beam-Foil Lifetime Studies of Highly Ionized Silicon

Abstract: Beam-foil lifetime studies of high1.v ionized silicon.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
38
0

Year Published

1980
1980
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 67 publications
(38 citation statements)
references
References 18 publications
(18 reference statements)
0
38
0
Order By: Relevance
“…A channeltron with a dark count rate <l/min is used as the detector. Further details of the experimental set-up can be found elsewhere [33]. A provisional detection efficiency curve of the monochromator/detector system (with the 600 l/mm grating) has been established [30].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…A channeltron with a dark count rate <l/min is used as the detector. Further details of the experimental set-up can be found elsewhere [33]. A provisional detection efficiency curve of the monochromator/detector system (with the 600 l/mm grating) has been established [30].…”
Section: Methodsmentioning
confidence: 99%
“…Experiment shows that particularly the Ly, radiation can easily be detected after much longer times because of the strong repopulation by cascades from ns levels and along the yrast line (levels with maximum orbital angular momentum 1 for a given principal quantum number n). The approximate shape of the detection window function (field-of-view plus efficiency of the grating) is used in the analysis of the decay curves [33].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A 6001/mm gold coated concave grating (~b~aze=12.7nm) serves as the disperging element. The channeltron detector is screened against secondary electrons by a negatively charged metal grid [18][19][20]. In the various hydrogenlike ions the transitions corresponding to Lye, Lyp, H a and H~ have been observed.…”
Section: Methodsmentioning
confidence: 99%
“…In the late 1970s, the Bochum beam-foil spectroscopy group began to measure EUV spectra and decay curves of B-like ions of Si and P [18][19][20][21][22][23]; references to various earlier calculations of oscillator strengths and transition rates are given in those papers. In the 1990s, the Bochum group returned to measurements of detailed processes in B-like ions, such as the massive changes of multiplet line intensity patterns (away from the standard expectation of LS coupling that had been tabulated 80 years ago by White and Eliason [24]), due to the changes in level mixing along the isoelectronic sequence [25].…”
Section: Earlier Workmentioning
confidence: 99%