2019 4th International Conference on Electrical Information and Communication Technology (EICT) 2019
DOI: 10.1109/eict48899.2019.9068796
|View full text |Cite
|
Sign up to set email alerts
|

Bangladesh Power System Peak Demand Shaving through Demand Side Management of the Battery Operated Easy Bike Load

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
26
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(27 citation statements)
references
References 4 publications
0
26
0
Order By: Relevance
“…The availability of gas filling stations enables the CNG auto rickshaws to have a comparatively higher range than E3Ws. E3W energy consumption is about 14 km/kWh (e.g., maximum range 150 km [14] with an overnight charge of 11 kWh [20]. However, CNG auto-rickshaws and E3Ws are mainly used as intra-city transportation media and travel almost identical distances on average.…”
Section: Prospects Of Electric Three-wheelers In Bangladeshmentioning
confidence: 99%
See 2 more Smart Citations
“…The availability of gas filling stations enables the CNG auto rickshaws to have a comparatively higher range than E3Ws. E3W energy consumption is about 14 km/kWh (e.g., maximum range 150 km [14] with an overnight charge of 11 kWh [20]. However, CNG auto-rickshaws and E3Ws are mainly used as intra-city transportation media and travel almost identical distances on average.…”
Section: Prospects Of Electric Three-wheelers In Bangladeshmentioning
confidence: 99%
“…The authors of [15,16] show how overnight charging of E3W is likely to impose negative pressure on the national grid in terms of high-power requirements. Demand-side management proposes to mitigate such a problem [20]. Renewable energy can incorporate into the charging infrastructure of the E3Ws [5,[21][22][23].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The overheating and the gassing of the battery may also be prevented by this system. [46] Another work by Verilli et al implying a direct load control DSM algorithm for peak shaving is carried out by considering the time-varying renewable generation (consists of two hydropower generators and PV panels), and thermal comfort of the buildings from residential heating system involving 50 buildings in Norwegian living lab in Steinkjer. The presented algorithm demanded a side operator that regulated the consumption by tracking the temperature using smart thermostats/controllers.…”
Section: Dsmmentioning
confidence: 99%
“…In the study by Awal et al, they presented the total load‐shifted percentages from peak to off‐peak hour, and the illustration of load shifting on account of timer control management, which shows a reduced peak load after applying the timer control system. [ 46 ] Besides, the shifted charging load does not show any bad impact on the power grid. The overheating and the gassing of the battery may also be prevented by this system.…”
Section: Dsmmentioning
confidence: 99%