2014
DOI: 10.1109/tpel.2014.2311046
|View full text |Cite
|
Sign up to set email alerts
|

Bandwidth Expansion Method for Circulating Current Control in Parallel Three-phase PWM Converter Connection System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 95 publications
(14 citation statements)
references
References 25 publications
0
13
0
Order By: Relevance
“…2(b). Therefore, in order to suppress the ZSCCs, we can adjust the relative duration of Pand N-type small vectors in pairs to make the AZSVs of parallel 3LT 2 Cs identical, just like the proposed method in [24] is to adjust the distribution of zero vectors of SVPWM by zero-sequence PI controller in parallel 2LC system, which has been proved to be easy to realize and accomplish good control effect in [25,26]. However, this method cannot be directly applied in the parallel-connected 3LT 2 Cs due to the complexity of AZSVs generated by three-level SVPWM.…”
Section: Analysis Of the Characteristics Of Svpwm For Zsccsmentioning
confidence: 99%
See 2 more Smart Citations
“…2(b). Therefore, in order to suppress the ZSCCs, we can adjust the relative duration of Pand N-type small vectors in pairs to make the AZSVs of parallel 3LT 2 Cs identical, just like the proposed method in [24] is to adjust the distribution of zero vectors of SVPWM by zero-sequence PI controller in parallel 2LC system, which has been proved to be easy to realize and accomplish good control effect in [25,26]. However, this method cannot be directly applied in the parallel-connected 3LT 2 Cs due to the complexity of AZSVs generated by three-level SVPWM.…”
Section: Analysis Of the Characteristics Of Svpwm For Zsccsmentioning
confidence: 99%
“…Moreover, if parallel system is equipped with TPSIs, we can extend the proposed method in [24] to suppress the remaining low-frequency ZSCCs by the closed-loop control. Note that, the disadvantage of the proposed method is that at a high modulation index range when the system saturates, the zero-sequence voltage of the follower converter cannot exactly follow the zero-sequence voltages of the master converter due to the lesser duration in the utilization of redundant vectors, which suffers the same limits as the two-level parallel case that suppress the ZSCCs by adjusting the distribution of the zero-vectors with the open-loop controller [22][23] and close-loop controller [24][25][26].…”
Section: Suppression Of the Remaining Low-frequency Zsccsmentioning
confidence: 99%
See 1 more Smart Citation
“…Improved modulation techniques are commonly-used active methods [28]. The voltage zero vector of space-vector-pulse-width modulation (SVPWM) is used in each paralleled module to suppress the circulating current [29,30]. However, the control performance deteriorates when the system parameters are different in each converter module.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the circulating fundamental and harmonic current, which are caused by the power back-feeding and line impedance mismatching, are harmful to the stable operation of the UPS system, as these circulating currents lead to the increased power losses and even overloading one of the UPS units. The circulating current issue has been investigated by some previous works [24][25][26][27][28]; [24,28] proposed the circulating suppression methods to deal with zero sequence current in the common DC-bus inverter system. The PWM switching strategies were investigated by [25][26][27] to solve the circulating current caused by the common mode voltage.…”
mentioning
confidence: 99%