“…So, the intercavity coupling constant k can not be measured as in the case of the periodic structure. But the method of k definition with an ultra low intercavity coupling constant was described in [7,9]. It consists in measuring the coupling factor β 1 of the system of two coupled cavities without the second cavity and the coupling factor β 1+2 with the connection between two cavities and the unloaded quality factors Q 01,02 .…”
Section: Description Of the Coupling Between The Cavitiesmentioning
confidence: 99%
“…Using [7,9] one can obtain the efficient of the parallel coupled accelerating structure, basing on the system of two coupled cavities (see figure 2). The equation…”
Section: Description Of the Coupling Between The Cavitiesmentioning
confidence: 99%
“…But the coupling slots between the exciting cavity and the accelerating cavities with the intercavity coupling constants from the table 2 can't be calculated with enough precision with help of simulation codes due to their extremely low values and enough complicated system. The size of coupling slots between the exciting and accelerating cavities was selected empirically on the base of the last experience [4,7,10] and convenience of manufacturing. The size of every slot is chosen 10×10×6 mm 3 .…”
The parallel coupled accelerating structure with a frequency of 2856 MHz is described. The cavities and the power propagation efficiencies are calculated. The results of the structure tuning are described. Analysis of the measurements and comparison with calculated data are provided. On the base of the measured parameters of the parallel coupled accelerating structure the beam energy under different meanings of the current is predicted.
“…So, the intercavity coupling constant k can not be measured as in the case of the periodic structure. But the method of k definition with an ultra low intercavity coupling constant was described in [7,9]. It consists in measuring the coupling factor β 1 of the system of two coupled cavities without the second cavity and the coupling factor β 1+2 with the connection between two cavities and the unloaded quality factors Q 01,02 .…”
Section: Description Of the Coupling Between The Cavitiesmentioning
confidence: 99%
“…Using [7,9] one can obtain the efficient of the parallel coupled accelerating structure, basing on the system of two coupled cavities (see figure 2). The equation…”
Section: Description Of the Coupling Between The Cavitiesmentioning
confidence: 99%
“…But the coupling slots between the exciting cavity and the accelerating cavities with the intercavity coupling constants from the table 2 can't be calculated with enough precision with help of simulation codes due to their extremely low values and enough complicated system. The size of coupling slots between the exciting and accelerating cavities was selected empirically on the base of the last experience [4,7,10] and convenience of manufacturing. The size of every slot is chosen 10×10×6 mm 3 .…”
The parallel coupled accelerating structure with a frequency of 2856 MHz is described. The cavities and the power propagation efficiencies are calculated. The results of the structure tuning are described. Analysis of the measurements and comparison with calculated data are provided. On the base of the measured parameters of the parallel coupled accelerating structure the beam energy under different meanings of the current is predicted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.