Balancing mobile-bearing unicondylar knee arthroplasty in vitro

Abstract: The results underline the importance of optimal balancing. Over-stuffing should be avoided as it results in the largest kinematic changes relative to the native condition and induces higher strains in the sMCL. Based on the kinematic findings, it is advisable to use thinner inlays, as long as this is not compromising stability or risking inlay luxation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
23
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 19 publications
(25 citation statements)
references
References 24 publications
2
23
0
Order By: Relevance
“…However, the lateral compartment pressure was not increased even in over-stuffed knees. 21 In our study, balancing the knee in the HL position did restore kinematics, which was closer to the native knee on Var-Val and rotational testing on area under the curve analysis. It has been our experience that balancing the knee in flexion is more difficult in the SL position.…”
Section: Discussionsupporting
confidence: 53%
See 2 more Smart Citations
“…However, the lateral compartment pressure was not increased even in over-stuffed knees. 21 In our study, balancing the knee in the HL position did restore kinematics, which was closer to the native knee on Var-Val and rotational testing on area under the curve analysis. It has been our experience that balancing the knee in flexion is more difficult in the SL position.…”
Section: Discussionsupporting
confidence: 53%
“…There is no consensus on what constitutes a well-balanced UKA due to a paucity of clinical and biomechanical data. 21 It has been proven in a cadaveric model that mobile bearing UKA leads to better restoration of kinematics in the unloaded state. Also, the presence of a mobile insert is likely to be beneficial during passive and squatting motion by preventing abnormal posterior translation of the medial femoral compartment.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Generally, ligament balance is subjectively assessed by the surgeon [13] and can be modified by altering the thickness of the polyethylene bearing. If chosen improperly by using either an under-or oversized polyethylene insert, the resulting tibiofemoral kinematics, contact pressure, and wear properties can be altered [14,15].While previous studies have documented the effect of bearing thickness on unicompartmental implants [16,17], there have been no studies documenting the influence on BCR TKA.…”
Section: Introductionmentioning
confidence: 98%
“…Different soft-tissue balancing based on implant positioning affects the kinematics of the knee in vitro . 25 …”
Section: Discussionmentioning
confidence: 99%