Bacterial Concentration Detection using a PCB-based Contactless Conductivity Sensor

Abstract: Capacitively coupled contactless conductivity detection (C4D) is an improved approach to avoid the problems of labor-intensive, time-consuming and insufficient accuracy of plate count as well as the high-cost apparatus of flow cytometry (FCM) in bacterial counting. This article describes a novel electrode-integrated printed-circuit-board (PCB)-based C4D device, which supports the simple and safe exchange of capillaries and improves the sensitivity and repeatability of the contactless detection. Furthermore, no… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
8
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 60 publications
(61 reference statements)
0
8
0
Order By: Relevance
“…By plotting Equation ( 7) versus the ratio r P,M /δ S , Figure 5 is obtained, where r P,M /δ S can be varied by changing the primary coil radius r P,M and the standard depth of penetration δ S depending on the sample conductivity and the excitation frequency according to Equation (5).…”
Section: Field Distribution In the Sample Compartmentmentioning
confidence: 99%
See 2 more Smart Citations
“…By plotting Equation ( 7) versus the ratio r P,M /δ S , Figure 5 is obtained, where r P,M /δ S can be varied by changing the primary coil radius r P,M and the standard depth of penetration δ S depending on the sample conductivity and the excitation frequency according to Equation (5).…”
Section: Field Distribution In the Sample Compartmentmentioning
confidence: 99%
“…Calculating the true depth of penetration δ T for the differential transformer used here with r P,M = 9.55 mm and d 0 = 11.25 mm, Equation ( 9) results in δ T = 7 mm, which is significantly lower than the δ S of approximately 1 m due to the relatively low conductivity of the medium κ (e.g., blood) and excitation frequency f according to Equation (5).…”
Section: Field Distribution In the Sample Compartmentmentioning
confidence: 99%
See 1 more Smart Citation
“…By adding “organisms” to the volume title, I was hoping for manuscripts beyond just cells. So, it was good to see that there were submissions of papers on zebrafish [1] and bacteria [2]. This volume highlights a diverse collection of research on single cell manipulation, diagnostics, cell migration, cell flow cytometry, to name a few.…”
mentioning
confidence: 99%
“…I see this as a positive development of more portable devices, which can be deployed remotely to, for example, perform diagnostics. Zhang et al [2] used conductivity to measure the concentration of bacteria.…”
mentioning
confidence: 99%